Electronic Modular Control Panel II+ (EMCP II+) Caterpillar


GSC CID 0100 - FMI 02 (for EUI Engines)

Usage:

3456 CBX
Conditions Which Generate This Code:

This diagnostic code is for the pressure sensor (engine oil).

The engine ECM monitors the engine oil pressure in order to protect the engine in case of a problem with the oil pressure. The oil pressure sensor is mounted on an oil gallery on the engine. The exact location of the engine oil pressure sensor varies depending on the engine model. The GSC+ monitors the oil pressure that is read by the engine ECM.

The possible causes of this diagnostic code are listed below:

  • There is an open in the circuit for the CAT data link. The open is between the engine ECM and the GSC+.

  • There is a short or a failure in the oil pressure sensor that is connected to the engine ECM.

The GSC+ issues a CID 0100 FMI 02 in order to show that the GSC+ is unable to receive any valid data about the oil pressure from the engine ECM.

The sensor is connected to the engine ECM. The engine ECM sends data about the oil pressure to the GSC+ via the CAT data link. Refer to Troubleshooting, RENR2227, "3406E and 3456 Generator Set Engines" for more information on the oil pressure sensor for the engine ECM.

System Response:

Note: The GSC+ is usually programmed to treat a problem with the oil pressure sensor as an alarm fault. Setpoint P04 is 0. The GSC+ can be programmed to treat a problem with the oil pressure sensor as a shutdown fault. Setpoint P04 is 1. When the GSC+ is programmed to treat the problem as a shutdown fault, it is not necessary to press the alarm code key in order to view the CID FMI. The diagnostic codes are automatically shown on the upper display.

Test Step 1. VERIFY THE DIAGNOSTIC CODE.

View the diagnostic code that is displayed on the upper display panel of the EMCP II+. Determine if the diagnostic code is originating from the Engine ECM.

Expected Result:

There is a letter "E" after the number of the CID that is on the upper display panel of the EMCP II+.

Results:

  • YES - There is a letter "E" after the number of the CID that is on the upper display panel of the EMCP II+ .

    Repair: Troubleshoot the diagnostic code for the Engine ECM. Refer to Troubleshooting, RENR2227, "3406E and 3456 Generator Set Engines" for information on troubleshooting the diagnostic code.

    Stop.

  • NO - There is not a letter "E" after the number of the CID that is on the upper display panel of the EMCP II+ .

    Repair: There may be a problem with the CAT Data Link. Determine if CID 0248 FMI 09 is present. Refer to Diagnostic Code Procedures, "GSC CID 0248 - FMI 09".

    Stop.

Caterpillar Information System:

Electronic Modular Control Panel II+ (EMCP II+) Troubleshooting Diagnostic Codes
Electronic Modular Control Panel II+ (EMCP II+) Indicators of Alarm Module or Remote Annunciator Are Constantly Flashing
Electronic Modular Control Panel II+ (EMCP II+) GSC Operation Is Erratic
3606, 3608, 3612 and 3616 Engines and C280-12, C280-16, C280-6 and C280-8 Marine Engines Control Panel Setpoints
Electronic Modular Control Panel II+ (EMCP II+) Engine Does Not Shutdown (for MUI Engines)
2001/05/01 Corrections to Specifications Module, SENR3863-01, "G3406 Engine" {1102}
3606, 3608, 3612 and 3616 Engines and C280-12, C280-16, C280-6 and C280-8 Marine Engines Control Panel Programmable Logic Controller
Electronic Modular Control Panel II+ (EMCP II+) Engine Does Not Shutdown (for EUI Engines)
3412C Engine Spacer Plate - Remove and Install
3412C Engine Fuel Injection Pump - Remove
3606, 3608, 3612 and 3616 Engines and C280-12, C280-16, C280-6 and C280-8 Marine Engines Control Panel Configuration
Electronic Modular Control Panel II+ (EMCP II+) Starting Motor Remains Engaged (for MUI Engines)
3412C Engine Automatic Timing Advance - Remove
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0100 - FMI 02 (for MUI and PEEC Engines)
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0100 - FMI 03
3412C Engine Automatic Timing Advance - Install
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0100 - FMI 04
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0110 - FMI 02 (for EUI Engines)
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0110 - FMI 02 (for MUI and PEEC Engines)
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0110 - FMI 03
Troubleshooting for Marine Engine Electronic Displays Electrical Connectors - Inspect
3412C Engine Automatic Timing Advance - Disassemble
2001/06/01 A New Magnetic Switch Assembly Replaces A Relay For The Air Starting Motor {7499}
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0110 - FMI 04
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.