Hot engine components can cause injury from burns. Before performing maintenance on the engine, allow the engine and the components to cool. |
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown. Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown. Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating. Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown. Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System. Failure to follow these instructions could result in personal injury or death. |
- Prepare the machine for maintenance. Refer to Operation and Maintenance Manual , "Prepare the Machine for Maintenance".
- Shutdown and de-energizing the machine. Refer to Operation and Maintenance Manual, "Electrical Shutdown and Voltage Discharge".
Show/hide table
Illustration 1 g03788142 - Disconnect clips (1). Remove bolts (2) and guard assembly (3).
Show/hide table
Illustration 2 g03788376 - Remove belt (4).
Show/hide table
Illustration 3 g03788416 - Disconnect clips (5).
Show/hide table
Illustration 4 g03788436 Show/hide tableIllustration 5 g03788449 - Pull back terminal covers (6). Remove nut (7) and bolt (9) to disconnect cable assembly (8) and cable assembly (10). Disconnect wire assembly (11).
Show/hide table
Illustration 6 g03788453 - Remove support assembly (12), guard assembly (13), and alternator (14).
- Install alternator (14) in the reverse order of removal.
- Tighten bolt (9) to a torque of
4.4 ± 1.0 N·m (39 ± 9 lb in) . - Tighten nut (7) to a torque of
18.2 ± 2.4 N·m (161 ± 21 lb in) .
- Tighten bolt (9) to a torque of