Remote Control Electrical Center For D10T and D11T
Illustration 1 | g02450396 |
Cover has been removed for clarity |
The Remote Control Electrical Center utilizes 16 relays. The relays are shown in Figure 2. Each relay is controlled via a sinking driver of the System Master (RCM). The RCM controls the 24 VDC relays.
The Remote Control Electrical Center is on the right side of the cab beneath the dash console.
Illustration 2 | g03795837 |
Illustration 3 | g03408635 |
The 16 Relays control the machine functions that are listed here:
- Fire Suppression
- Horn
- Parking Brake Switch Disable
- Implement Lockout Bypass
- RC Auxiliary
- Cylinder Lights
- Ripper Light
- Camera Wash
- Forward ROPS Lights 1
- Fender/ Forward ROPS Lights 2
- Mode Select
- Machine Power
- Cab Key Disable
- Engine Start
- Rear ROPS Lights 1
- Rear ROPS Lights 2
The Remote Control ECM uses a 24VDC signal via a sinking driver of the remote control ECM to energize these relays. Refer to the Systems Operation section for detailed information on relay functions.
Remote Control Electrical Center For D8T
Illustration 4 | g06266990 |
Cover has been removed for clarity |
The Remote Control Electrical Center utilizes 10 relays. The relays are shown in Illustration 4. The RCM controls the 24 VDC relays.
The Remote Control Electrical Center is on top of the cab underneath the RMEE.
Illustration 5 | g06266994 |
Remote control electrical center film |
Illustration 6 | g06266997 |
Illustration 7 | g03408635 |
The 10 Relays control the machine functions that are listed here:
- R1 Engine Start
- R2 Machine Power
- R3 Auxiliary Power
- R4 Fire Suppression
- R5 Park Brake 1
- R6 Key Disable
- R7 Mode Select
- R8 Machine Horn
- R9 Implement Lockout
- R10 Park Brake 2