- Material Handler:
- MH3037 (S/N: KPM1-208)
- MH3049 (S/N: HPB1-234)
- MH3059 (S/N: RBR1-215)
- MH3049 (S/N: HPB1-234)
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.
Problem
Machines listed above equipped with a generator may have the wiring in the electrical box on the generator wired incorrectly.
Solution
The wiring in the electrical box should be checked to verify correct wiring connections for proper polarity during generator operation. The following connections are how the generator wires should be connected to the harness wires in the electrical box on the generator.
Generator Wiring Connections     | ||||
---|---|---|---|---|
Item     | Wire Code     |     | Item     | Wire Code     |
(1)     | "F1" (gray) wire     | Connects to     | (2)     | "F1" (blue) wires     |
(3)     | "F2" (gray) wire     | Connects to     | (4)     | "F2" (red) wires     |
(5)     | "P1" (gray) wire     | Connects to     | (6)     | "P1" (white) wire     |
(7)     | "P2" (gray) wire     | Connects to     | (8)     | "P2" (green) wire     |
(9)     | "A2" (black) wire     | Connects to     | (10)     | "S2" (black) wire     |
(11)     | "A1" (black) wire     | Connects to     | (12)     | Positive (black w/red) wire     |
(13)     | "S1" (black) wire     | Connects to     | (14)     | Negative (black w/black) wire     |
Illustration 1 | g03674467 |
(1) "F1" (gray) wire (2) "F1" (blue) wires (3) "F2" (gray) wire (4) "F2" (red) wires (5) "P1" (gray) wire (6) "P1" (white) wire (7) "P2" (gray) wire (8) "P2" (green) wire (9) "A2" (black) wire (10) "S2" (black) wire (11) "A1" (black) wire (12) Positive (black w/red) wire (13) "S1" (black) wire (14) Negative (black w/black) wire |