Configuration Screens
Press the tab button on the display to access the configuration screen. The operator will only be able to view the current system setting the first time that the configuration screen is accessed.
To edit the settings, the operator must first press the "OK" button. After entering the edit mode, the first parameter in the list that can be configured will be highlighted. The parameter must be highlighted in order to allow the parameter to be changed. Press the left arrow or the right arrow on the arrows button to change the highlighted parameter.
Navigation between parameters is accomplished by pressing the top and bottom parts of the arrows button. Any changes that are made to parameters will not become active until the operator has pressed the "OK" button to exit the edit mode. An example of the configuration screen is shown in Illustration 1.
Illustration 1 | g02304479 |
Illustration 1 shows the view that appears on the display when the configure screen is accessed for the first time. The "Change Settings" box will be located opposite the "OK" button to indicate the purpose of the button. The "Change Screens" box will be located opposite the tab button to indicate the purpose of the button. After pressing the "OK" button, the screen will change to the following view that is indicated by Illustration 2.
Illustration 2 | g02304481 |
Configure Parameters
The following list of parameters can be configured when the "Change View" screen is accessed.
Language
The display supports the following list of languages:
- English
- French
- Indonesian
- Portuguese
- Spanish
Auto Dimming for the Camera View
The auto dim feature will reduce the display and video brightness by one third of the current brightness setting. When night mode is selected, the entire screen will be dimmed.
Auto dimming can be either "Enabled" or "Disabled".
Object Detection System Enable Delay
Note: This parameter is only adjustable when Caterpillar Electronic Technician (Cat ET) is connected and communicating with the system.
This parameter configures the delay time that will be used by the object detection system to delay the activation of the object detection system after the machine comes to a stop.
When the machine stops for "x" seconds the system returns to active mode. This delay can be set from 0 to 30 seconds.
Once the operator has changed all the desired settings, pressing the "OK" button will make the view return to the first configuration screen. The operator will not be able to exit the configuration screen until the operator exits the edit mode.
Object Detection Standby Mode
Note: This parameter is only adjustable when Caterpillar Electronic Technician (Cat ET) is connected and communicating with the system.
The system can be configured to run in one of two different modes:
Distance - In "Distance" based standby, once the machine travels 20 m (65 ft) the system goes into standby mode. When the machine stops for "x" seconds the system returns to active mode. The "x" seconds are set in the "Object Detection System Enable Delay" dialog. This delay can be set from 0 to 30 seconds.
Speed - In "Speed" based standby, once the machine travels above 11 km/h (7 mph) the system enters standby mode. When the machine slows down to below 4.8 km/h (3 mph) the system returns to active mode.