Removal Procedure
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, all hoses and all tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
- Drain the additive tank into a suitable container.
- Remove clamp (2) and the hose from diaphragm pump (3) .
Illustration 1 | g01316916 |
- Remove clamp (4) and the hose from diaphragm pump (3) .
- Disconnect harness assembly (5) .
- Remove bolts (1) and diaphragm pump (3) .
Installation Procedure
- Install diaphragm pump (3) and bolts (1) .
Illustration 2 | g01316916 |
- Connect harness assembly (5) .
- Install the hose to diaphragm pump (3) and install clamp (4) .
- Install the hose to diaphragm pump (3) and install clamp (2) .