TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Caterpillar


Input High Error IQAN XT2 A0-25

Usage:

TK711 101
Conditions Which Generate This Code:


Illustration 1g01294996

Connections for the hydraulic filter bypass switch

This diagnostic code is associated with the hydraulic filter bypass switch. The "Input high error" means that the IQAN-XT2 module has determined that the voltage of the circuit for the switch is above normal.

The possible causes of this diagnostic code are listed below:

  • The signal circuit for the switch is shorted to ground.

  • The switch has failed.

  • The module has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of "Input high error" for pin 25 of the IQAN-XT2 module is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SWITCH

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Ensure that the diagnostic code is active.

  1. Observe the status of the diagnostic code. Disconnect the machine harness from the switch.

Expected Result:

The "Input high error" for pin 25 of the IQAN-XT2 module remains active.

Results:

  • OK - The diagnostic code remains active. The switch is correct. Proceed to Test Step 2.

  • NOT OK - The diagnostic code is no longer active. The switch has failed.

    Repair: Replace the switch.

    STOP

Test Step 2. CHECK THE WIRING HARNESS OF THE SWITCH FOR A SHORT TO GROUND

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness from the switch.

  1. Disconnect the machine harness connectors from the IQAN-XT2 module.

  1. At the machine harness connector for the module, measure the resistance from the signal contact IQAN XT2 A0 - 25 (wire E455-BR) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the module.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness.

    Repair: The short is between signal contact IQAN XT2 A0 - 25 (wire E455-BR) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors making sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the "Input high error" for pin 25 of the IQAN-XT2 module.

Expected Result:

The "Input high error" for pin 25 of the IQAN-XT2 module is active.

Results:

  • YES - The "Input high error" for pin 25 of the IQAN-XT2 module is active. The diagnostic code has not been corrected. The module may have failed.

    Repair: If the problem is still present, replace the switch. After the switch is replaced, perform this test step again. After switch replacement, if the problem is still present, the module may be faulty.Exit this procedure and perform the diagnostic code procedure again. If the problem persists, the module may have failed. Prior to replacing a module, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found, replace the module.

    STOP

  • NO - The "Input high error" for pin 25 of the IQAN-XT2 module is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

793D Off-Highway Truck Power Train Flow Control and Relief Valve (Rear Axle Oil) - Assemble
793D Off-Highway Truck Power Train Flow Control and Relief Valve (Rear Axle Oil) - Disassemble
572R Series II Pipelayer Transmission Magnetic Screen - Clean
Procedure for Kidney Looping Wheel Harvester and Site Prep Tractor Hydraulic Oil{0680, 0738, 0768, 3000, 5050, 5056} Procedure for Kidney Looping Wheel Harvester and Site Prep Tractor Hydraulic Oil{0680, 0738, 0768, 3000, 5050, 5056}
2006/08/14 An Improved Weld Is Now Used on the Undercarriage on Track Feller Bunchers {4150}
16M Motor Grader Transmission and Differential Oil Level - Check
793D Off-Highway Truck Power Train Transmission Hydraulic Control - Install
793D Off-Highway Truck Power Train Transmission Hydraulic Control - Remove
C15 Petroleum Generator Set Engines Coolant Temperature Sensor
572R Series II Pipelayer Transmission System Oil Sample - Obtain
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-35
572R Series II Pipelayer Transmission System Oil Filter - Replace
C15 Petroleum Generator Set Engines Inlet Air Temperature Sensor
PL61 Pipelayer Fuel System Primary Filter - Clean/Replace
C-9 Engines for Caterpillar Built Machines Speed/Timing Sensor
2006/08/14 A New Saw Pump Is Used on Track Feller Bunchers {5070}
IT38H Integrated Toolcarrier and 938H Wheel Loader Axle Oil Cooler Magnetic Filter - Clean/Replace
IT38H Integrated Toolcarrier and 938H Wheel Loader Cab Air Filter - Clean/Replace
AS2302 Screed Extender Carriage
777G Off-Highway Truck Power Train Duo-Cone Seals - Install
2006/11/06 New Seal Kit for Fan Motors {1386, 5061}
PM-201 Cold Planer Rotor Coolant Level - Check - Drum with Three-Piece Rotor Bits
IT38H Integrated Toolcarrier and 938H Wheel Loader Engine Crankcase Breather - Clean - If Equipped
IT38H Integrated Toolcarrier and 938H Wheel Loader Fuel Tank Water and Sediment - Drain
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.