TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Caterpillar


Input High Error IQAN XT2 A0-35

Usage:

TK711 101
Conditions Which Generate This Code:


Illustration 1g01294832

Connections for the hydraulic oil level switch

This diagnostic code is associated with the hydraulic oil level switch. The "Input high error" means that the IQAN-XT2 module has determined that the voltage of the circuit for the switch is above normal.

The possible causes of this diagnostic code are listed below:

  • The signal circuit for the switch is shorted to ground.

  • The switch has failed.

  • The module has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of "Input high error" for pin 35 of the IQAN-XT2 module is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SWITCH

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Ensure that the diagnostic code is active.

  1. Observe the status of the diagnostic code. Disconnect the machine harness from the switch.

Expected Result:

The "Input high error" for pin 35 of the IQAN-XT2 module remains active.

Results:

  • OK - The diagnostic code remains active. The switch is correct. Proceed to Test Step 2.

  • NOT OK - The diagnostic code is no longer active. The switch has failed.

    Repair: Replace the switch.

    STOP

Test Step 2. CHECK THE WIRING HARNESS OF THE SWITCH FOR A SHORT TO GROUND

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness from the switch.

  1. Disconnect the machine harness connectors from the IQAN-XT2 module.

  1. At the machine harness connector for the module, measure the resistance from the signal contact IQAN XT2 A0 - 35 (wire 496-WH) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the module.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - One or more resistance measurements is not correct. There is a short in the machine harness.

    Repair: The short is between signal contact IQAN XT2 A0 - 35 (wire 496-WH) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors making sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the "Input high error" for pin 35 of the IQAN-XT2 module.

Expected Result:

The "Input high error" for pin 35 of the IQAN-XT2 module is active.

Results:

  • YES - The "Input high error" for pin 35 of the IQAN-XT2 module is active. The diagnostic code has not been corrected. The module may have failed.

    Repair: If the problem is still present, replace the switch. After the switch is replaced, perform this test step again. After switch replacement, if the problem is still present, the module may be faulty.Exit this procedure and perform the diagnostic code procedure again. If the problem persists, the module may have failed. Prior to replacing a module, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found, replace the module.

    STOP

  • NO - The "Input high error" for pin 35 of the IQAN-XT2 module is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

572R Series II Pipelayer Transmission System Oil Filter - Replace
572R Series II Pipelayer Transmission System Oil Level - Check
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-36
572R Series II Pipelayer Transmission System Oil - Change
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-39
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-38
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-37
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-23
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-22
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-21
14M Motor Grader Oil Filter (Implement Controls) - Replace
2006/09/11 Shims are Now Used in the Belt Tightener Group {1358}
572R Series II Pipelayer Transmission System Oil Sample - Obtain
C15 Petroleum Generator Set Engines Coolant Temperature Sensor
793D Off-Highway Truck Power Train Transmission Hydraulic Control - Remove
793D Off-Highway Truck Power Train Transmission Hydraulic Control - Install
16M Motor Grader Transmission and Differential Oil Level - Check
2006/08/14 An Improved Weld Is Now Used on the Undercarriage on Track Feller Bunchers {4150}
Procedure for Kidney Looping Wheel Harvester and Site Prep Tractor Hydraulic Oil{0680, 0738, 0768, 3000, 5050, 5056} Procedure for Kidney Looping Wheel Harvester and Site Prep Tractor Hydraulic Oil{0680, 0738, 0768, 3000, 5050, 5056}
572R Series II Pipelayer Transmission Magnetic Screen - Clean
793D Off-Highway Truck Power Train Flow Control and Relief Valve (Rear Axle Oil) - Disassemble
793D Off-Highway Truck Power Train Flow Control and Relief Valve (Rear Axle Oil) - Assemble
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-25
C15 Petroleum Generator Set Engines Inlet Air Temperature Sensor
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.