Illustration 1 | g00827997 |
203-5533 Bank Valve (Six) |
(1) Extendable stick control valve
(2) Stick control valve
(3) Bucket control valve
(4) Swing control valve
(5) Boom control valve
(6) Work tool control valve
(7) Torque for the plug ... 70.0 ± 7.0 N·m (52.00 ± 5.00 lb ft)
(8) Inlet
(9) Torque for the relief valve ... 70.0 ± 7.0 N·m (52.00 ± 5.00 lb ft)
(10) Solenoid valve group for the hydraulic shutoff circuit
- Torque for nut (11) ... 9.5 ± 1.5 N·m (7.00 ± 1.00 lb ft)
- Torque for the solenoid ... 50.0 ± 5.0 N·m (37.00 ± 3.00 lb ft)
- Nominal voltage for the coil ... 12 VDC
- Maximum voltage ... 14.5 VDC
- Resistance at a temperature of 25.0° ± 5.0°C (77.00° ± 9.00°F) ... 10.5 ± 0.3 Ohms
- Torque for the solenoid ... 50.0 ± 5.0 N·m (37.00 ± 3.00 lb ft)
(12) Torque for the O-ring plug ... 14.0 ± 1.0 N·m (10.00 ± 1.00 lb ft)
(13) Torque for the plug ... 70.0 ± 0.5 N·m (52.00 ± 0.40 lb ft)
(14) Outlet
(15) Torque for the nuts ... 27.0 ± 3.0 N·m (20.00 ± 2.00 lb ft)
Note: Place three 4T-2723 Shims between the valve sections during assembly. Place one shim over each stud. The shims are necessary in order to prevent the spool from binding in the valve body.