150-5405 Metering Pump with Crossovers
Illustration 1 | g00514299 |
(1) Pin. (2) Gerotor. (3) Drive. (4) Bolts. (5) High capacity cylinder relief valve. (6) Anticavitation valve. (7) Plug for the check valve for the manual steering. (8) Check valve. |
The pin (1) in the body must be aligned with gerotor (2) and drive (3) .
(4) Tighten the bolts in the sequence that is shown. Torque for the seven bolts ... 14 ± 3 N·m (10.0 ± 2.0 lb ft)
(4) Final torque for the seven bolts ... 28 ± 3 N·m (21.0 ± 2.0 lb ft)
(5) Setting for the high capacity cylinder relief valve ... 25900 kPa (3750 psi)
(7) Torque for the plug ... 11 ± 2 N·m (95.0 ± 18.0 lb in)
(7) The plug must be flush with the mounting surface or below the mounting surface.
149-4830 Metering Pump
Illustration 2 | g00514376 |
(1) Pin. (2) Gerotor. (3) Drive. (4) Bolts. (5) Plug for the check valve for the manual steering. (6) Check valve. |
The pin (1) in the body must be aligned with gerotor (2) and drive (3) .
(4) Tighten the bolts in the sequence that is shown. Torque for the seven bolts ... 14 ± 3 N·m (10.0 ± 2.0 lb ft)
(4) Final torque for the seven bolts ... 28 ± 3 N·m (21.0 ± 2.0 lb ft)
(5) Torque for the plug ... 11 ± 2 N·m (95.0 ± 18.0 lb in)
(5) The plug must be flush with the mounting surface or below the mounting surface.