Illustration 1 | g00402222 |
Torque for the two studs which is used to mount the pump to the case and frame ... 30 ± 4 N·m (22 ± 3 lb ft)
(1) Torque for four bolts that hold the cage to the cover ... 30 ± 4 N·m (22 ± 3 lb ft)
(2) Apply 7M-7260 Liquid Gasket to plug (2). Install the plug to the following depth below the flange surface. ... 1.25 ± 0.25 mm (0.05 ± 0.010 inch)
Note: The pump must turn freely before assembly of the pump to the case and frame and after assembly of the pump. ()
Section     | Function     | Rotation     | Output (min)     | RPM     | Pressure     |
---|---|---|---|---|---|
A     | Torque Converter and Lubrication     | Counterclockwise     | 135 L/min (35 US gpm)     |
1800     | 1035 kPa (150 psi)     |
B     | Transmission and Controls     | Counterclockwise     | 70 L/min (18.2 US gpm)     |
1800     | 2760 kPa (400 psi)     |
C     | Transmission and Torque Converter Scavenge Line     | Counterclockwise     | 107 L/min (28 US gpm)     |
1800     | 70 kPa (10 psi)     |
Illustration 2 | g00402223 |
(3) Clearance between the gears and the cover in Section "C" in a new pump ... 0.104 ± 0.043 mm (0.0041 ± 0.0017 inch)
(4) Clearance between the gears and the body in Section "B" of a new pump ... 0.104 ± 0.043 mm (0.0041 ± 0.0017 inch)
(5) Clearance between the gears and the cover in Section "A" of a new pump ... 0.107 ± 0.021 mm (0.0042 ± 0.0008 inch)
(6) Diameter of new shafts ... 31.742 ± 0.005 mm (1.2497 ± 0.0002 inch)
(7) Bore of new bearings ... 31.786 ± 0.008 mm (1.2514 ± 0.0003 inch)