Illustration 1 | g00610221 |
(1) Apply 9S-3263 Thread Lock Compound to the bolt threads at assembly.
(2) Torque for the plug ... 100 ± 5 N·m (74 ± 4 lb ft)
(3) Apply 9S-3263 Thread Lock Compound to the bolt threads at assembly.
(4) Torque for the plug ... 100 ± 15 N·m (74 ± 11 lb ft)
The weight of the 7X-5305 Shot must total 8.3 kg (18.3 lb).
(5) Torque for the two plugs ... 90 ± 15 N·m (66 ± 11 lb ft)
Note: In order to fill the reservoir, the position of the fill/drain plug must be located at the top of the rotation.
(6) Rotate the lobe of the weight downward. Orient the "T" upward on the splined shaft. The total shaft end play should be .50 mm (0.02 inch) to1.35 mm (0.05 inch). The assembled housing should be capable of holding 70 kPa (10 psi) static air pressure and 35 kPa (5 psi) static vacuum.
Note: Flush the eccentric weight housing after assembly. A level of "ISO 19/16" or less is required.