Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact the skin. |
Obtain the Sample and the Analysis
In addition to a good preventive maintenance program, Caterpillar recommends using S·O·S oil analysis at regular scheduled intervals in order to monitor the condition of the differential and the final drives.
Each oil sample should be taken when the oil is warm and when the oil is well mixed in order to ensure that the sample is representative of the oil in the differential or final drive.
Obtain the S·O·S Sample
Illustration 1 | g00296553 |
Final Drive Filler Plug |
Use a 1U-5758 Vacuum Pump in order to obtain an S·O·S oil sample from the final drive.
Illustration 2 | g00296554 |
Drain plug for the differential and bevel gear case |
Perform the drain stream method in order to obtain an oil sample from the bevel gear case.
The recommended oil change interval is every 2000 hours. The recommended interval for oil samples is every 250 hours. The oil type is TDTO. Refer to Operation and Maintenance Manual, "S·O·S Oil Analysis".
To avoid contamination of the oil samples, the tools and the supplies that are used for obtaining oil samples must be clean.
Refer to Special Publication, PEHP6001 for more information on obtaining a good oil sample. Consult your Caterpillar dealer for complete information and assistance in establishing an S·O·S program for your machine.