Usage:
426C (1CR, 1MR),
436C (1FR, 1PR),
438C (1JR, 1TR) Backhoe Loaders
Incorrect part numbers and lengths are specified, in some service publications, for bolts used with the 142-7539 Metering Pump and the 142-7549 Metering Pump. See the Illustration for correct part numbers, lengths, and tightening sequence of bolts for both metering pumps.
Tighten all seven bolts, dry, in sequence T1-T7, to a torque of 14 ± 3 N·m (10 ± 2 lb ft) and then, in the same sequence, to a final torque of 28 ± 3 N·m (21 ± 2 lb ft).
Correct Length and Tightening Sequence for Bolts