3512C Marine Auxiliary Generator Set Engines with Dynamic Gas Blending Caterpillar


Sensor Supply - Test

Usage:

3512C GDM
Use this procedure to troubleshoot the electrical system if a problem is suspected with a sensor supply. Also, use this procedure if one of the following diagnostic codes is active or easily repeated.

Table 1
Diagnostic Codes Table    
J1939 Code and Description     Conditions which Generate this Code     System Response    
678-3
ECU 8 Volts DC Supply : Voltage Above Normal    
The digital sensor supply voltage is above normal for two seconds.     The code is logged.
All sensors are set to default values.    
678-4
ECU 8 Volts DC Supply : Voltage Below Normal    
The digital sensor supply voltage is below normal for two seconds.     The code is logged.
All sensors are set to default values.    
3509-3
Sensor Supply Voltage 1 : Voltage Above Normal    
The analog sensor supply voltage is above normal for two seconds.     The code is logged.
All sensors are set to default values.    
3509-4
Sensor Supply Voltage 1 : Voltage Below Normal    
The analog sensor supply voltage is below normal for two seconds.     The code is logged.
All sensors are set to default values.    
3510-3
Sensor Supply Voltage 2 : Voltage Above Normal    
The analog sensor supply voltage is above normal for two seconds.     The code is logged.
All sensors are set to default values.    
3510-4
Sensor Supply Voltage 2 : Voltage Below Normal    
The analog sensor supply voltage is below normal for two seconds.     The code is logged.
All sensors are set to default values.    
108-21
Atmospheric Pressure Sensor : Data Drifted Low    
The 5 VDC supply to the sensor has been lost.     The code is logged.
All sensors are set to default values.    
3563-21
Engine Intake Manifold #1 Absolute Pressure : Data Drifted Low    
The 5 VDC supply to the sensor has been lost.     The code is logged.
All sensors are set to default values.    
5578-21
Engine Fuel Delivery Absolute Pressure : Data Drifted Low    
The 5 VDC supply to the sensor has been lost.     The code is logged.
All sensors are set to default values.    
5580-21
Engine Fuel Delivery Absolute Pressure : Data Drifted Low    
The 5 VDC supply to the sensor has been lost.     The code is logged.
All sensors are set to default values.    

System Operation

The Electronic Control Module (ECM) supplies a regulated voltage of 5.0 ± 0.2 VDC to the following sensors:

  • Atmospheric pressure sensor

  • Crankcase pressure sensor

  • Filtered engine oil pressure sensor

  • Filtered fuel pressure sensor

  • Gas pressure sensor

  • Intake manifold pressure sensor

  • Left turbocharger inlet pressure sensor

  • Right turbocharger inlet pressure sensor

  • Unfiltered engine oil pressure sensor

  • Unfiltered fuel pressure sensor

The ECM supplies a regulated voltage of 8.0 ± 0.4 VDC to the following sensors:

  • Left turbocharger turbine inlet temperature sensor

  • Right turbocharger turbine inlet temperature sensor

The supply voltage for the sensors is routed from the ECM to terminal 1 of each sensor connector. The sensor return for the sensors is routed from the ECM to terminal 2 of each sensor connector. The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.

If applicable, when a -10 code is logged, this code indicates that the 5 V supply is not available at the sensor connector. During normal engine operation, each of the signals from the pressure sensors fluctuate slightly. When the 5 V supply becomes unavailable at the pressure sensor connector, the signal from that sensor floats to a midrange value. The signal will not fluctuate. If the signal from the sensor remains abnormally steady for more than 30 seconds, the ECM will activate this code.

Note: The sensors are not protected from overvoltage. A short from the supply line to the +Battery may damage the sensors. Repair the sensor supply and check for any active sensor diagnostic codes in order to determine if a sensor has failed.




Illustration 1g03658153

Analog sensors schematic




Illustration 2g03658061

PWM sensors schematic




Illustration 3g03658767

P1 ECM connector

(P1-3) Analog return

(P1-4) Digital supply

(P1-5) Digital return

(P1-15) Left turbo inlet pressure

(P1-18) Digital return

(P1-27) Right turbo inlet pressure




Illustration 4g03658768

P2 ECM connector

(P2-15) Intake manifold pressure

(P2-16) Unfiltered fuel pressure

(P2-17) Analog return

(P2-27) Filtered fuel pressure

(P2-28) Filtered oil pressure

(P2-33) Crankcase pressure

(P2-41) Gas pressure

(P2-54) Analog return

(P2-65) Right turbocharger turbine inlet temperature

(P2-66) Unfiltered oil pressure

(P2-72) Analog sensor supply

(P2-73) Left turbocharger turbine inlet temperature

(P2-78) Barometric pressure

(P2-80) Analog sensor supply

(P2-81) Analog sensor supply

(P2-83) Analog return




Illustration 5g01240891

Sensor connector

(Terminal 1) Sensor supply

(Terminal 2) Sensor return

(Terminal 3) Signal

Table 2
Troubleshooting Test Steps     Values     Results    

1. Inspect the Electrical Connectors and the Wiring

A. Turn the main disconnect switch to the OFF position.

B. Thoroughly inspect connectors (1) through (7). Inspect all of the connectors that are associated with the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.

C. Perform a
45 N (10 lb) pull test on each of the wires in the ECM connectors that are associated with the circuit.

D. Check the allen head screw for each of the ECM connectors for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.

E. Check the harness and wiring for abrasion and for pinch points from the sensors back to the ECM.
   

Connectors and Wiring    

Result: The connectors and/or wiring appear to be OK.

Proceed to Test Step 2.

Result: There is a problem with the connectors and/or wiring.

Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are coupled.

Verify that the repair eliminated the problem.
   

2. Check for Active Codes and Logged Codes

A. Connect Caterpillar Electronic Technician (ET) to the service tool connector.

B. Restore the electrical power to the ECM.

C. Monitor the active diagnostic code screen on Cat ET. Check and record any diagnostic codes that are active or logged. Look for the following diagnostic codes:

- 678-3
- 678-4
- 3509-3
- 3509-4
- 3510-3
- 3510-4
- 108-21
- 3563-21
- 5578-21
- 5580-21

Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

D. Turn the main disconnect switch to the OFF position.
   

Codes    

Result: A code is not active or logged.

Repair: There does not appear to be an electrical problem with the sensor supply at this time. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".

Result: A 678-3 or 678-4 diagnostic code is active or logged.

There is an electrical problem with the digital sensor supply.

Proceed to Test Step 6.

Result: A 3509-3, 3509-4, 3510-3, or 3510-4 diagnostic code is active or logged.

There is an electrical problem with the analog sensor supply.

Proceed to Test Step 4.

Result: A 108-21, 3563-21, 5578-21, or 5580-21 diagnostic code is active or logged.

The analog supply is not reaching the sensor.

Proceed to Test Step 3.
   

3. Check the Supply Voltage at the Sensor Connector

A. Disconnect the harness connectors for the following sensors:

- Atmospheric pressure sensor
- Crankcase pressure sensor
- Intake manifold pressure sensor
- Filtered oil pressure sensor
- Unfiltered oil pressure sensor
- Filtered fuel pressure sensor
- Unfiltered fuel pressure sensor
- Gas pressure sensor
- Left turbocharger inlet pressure sensor
- Right turbocharger inlet pressure sensor

B. Restore the electrical power to the appropriate ECM.

Note: Be sure to wiggle the harness during the following measurements in order to reveal an intermittent condition.

C. Measure the voltage between terminals 1 and 2 at the appropriate sensor connector.

D. Turn the main disconnect switch to the OFF position.

E. Connect all of the sensors.
   

5.0 ± 0.2 VDC    

Result: Each voltage measurement is 5.0 ± 0.2 VDC.

Repair: The analog supply is reaching the sensor connector. There may be a problem with the sensor. Perform the following procedure:

1. Clear all diagnostic codes.

2. Run the engine. Allow the engine to warm up. Check if the code has been logged again.

If the code becomes active or logged, the sensor is faulty. Replace the sensor.

Verify that the repair eliminated the problem.

If the code does not become active or logged, there may be an intermittent problem in the harness or in a connector. If an intermittent problem is suspected, refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct troubleshooting procedure.

Result: At least one voltage measurement is not 5.0 ± 0.2 VDC. There is a problem with the harness wiring or with the ECM.

Proceed to Test Step 4.
   

4. Disconnect the Analog Sensors While You Check for Active Diagnostic Codes

A. Restore the electrical power to the ECM.

B. Monitor the active diagnostic code screen on Cat ET while you disconnect each 5 V sensor at the sensor connector. Check for an active 3509-3, 3509-4, 3510-3, or 3510-4 code.

Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

C. For a problem with the supply at the primary ECM, disconnect the following sensors one at a time:

- Atmospheric pressure sensor
- Crankcase pressure sensor
- Intake manifold pressure sensor
- Filtered oil pressure sensor
- Unfiltered oil pressure sensor
- Filtered fuel pressure sensor
- Unfiltered fuel pressure sensor
- Gas pressure sensor
- Left turbocharger inlet pressure sensor
- Right turbocharger inlet pressure sensor

D. Turn the main disconnect switch to the OFF position.
   

Analog Sensors    

Result: The diagnostic code deactivates when a particular sensor is disconnected.

Repair: Connect the suspect sensor. If the code returns, replace the sensor. Connect all of the connectors.

Verify that the repair eliminated the problem.

Result: The diagnostic code remains active after all of the sensors are disconnected. The sensors are not the cause of the diagnostic code. Leave the sensors disconnected.

Proceed to Test Step 5.
   

5. Check the Analog Supply Voltages at the ECM

A. Disconnect the J1/P1 and J2/P2 connectors from the appropriate ECM.

B. Fabricate five jumper wires that are long enough to be used to measure the supply voltage at the ECM connector. Crimp connector sockets to one end of each jumper wire.

C. Remove the wires from the sensor supplies at the following terminal locations:

- P2-72
- P2-80
- P2-81

Also remove the wires from the analog returns at the following terminal locations:

- P2-17
- P2-54
- P2-83

Install a jumper wire into each of these terminal locations.

D. Connect the ECM connectors.

E. Restore electrical power to the engine ECM.

F. One at a time, measure the voltage between the jumpers in each of the sensor supplies listed above and the jumper for the analog return.

G. Turn the main disconnect switch to the OFF position.
   

5.0 ± 0.2 VDC    

Result: The voltage measurement is 5.0 ± 0.2 VDC.

Repair: The ECM is operating correctly. The supply wire that is in the harness is shorted to another wire in the harness or the supply wire is shorted to engine ground. Repair the harness wiring that is between the sensor and the ECM connector.

Verify that the repair eliminated the problem.

Result: The voltage measurement is not 5.0 ± 0.2 VDC.

Repair: The ECM is not producing the correct supply voltage. There appears to be a problem with the ECM. Replace the ECM. Refer to Troubleshooting, "Test ECM Mode".

Note: Before you consider replacing the ECM, consult with the Dealer Solutions Network (DSN) for assistance.

Verify that the repair eliminated the problem.
   

6. Disconnect the Digital Sensors while you Check for Active Diagnostic Codes

A. Restore the electrical power to the ECM.

B. Monitor the active diagnostic code screen on Cat ET while you disconnect each of the digital sensors at the sensor connector. Check for an active 678-3 code or an active 678-4 code.

Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

C. Disconnect the following sensors one at a time:

- Sensor for the left turbocharger turbine inlet temperature
- Sensor for the right turbocharger turbine inlet temperature

D. Turn the main disconnect switch to the OFF position.
   

Codes    

Result: The diagnostic code deactivates when a particular sensor is disconnected.

Repair: Connect the suspect sensor. If the code returns, replace the sensor. Connect all of the connectors.

Verify that the repair eliminated the problem.

Result: The diagnostic code remains active after the sensors are disconnected. Leave the sensors disconnected. The sensors are not the cause of the diagnostic code.

Proceed to Test Step 7.
   

7. Check the Digital Supply Voltage at the ECM

A. Disconnect the J2/P2 and J1/P1 ECM connector.

B. Fabricate three jumper wires that are long enough to be used to measure the supply voltage at the ECM connectors. Crimp connector sockets to one end of each jumper wire.

C. Remove the wires from terminal locations P1-4 (digital sensor supply) P1-5 (digital return) and P1-18 (digital return). Install a jumper wire into each of these terminal locations.

D. Connect the J2/P2 ECM connector.

E. Restore electrical power to the engine ECM.

F. Measure the voltage between the jumper wire in P1-4 (digital sensor supply) and P1-5 (sensor return).

G.Measure the voltage between the jumper wire in P1-4 (digital sensor supply) and P1-18 (sensor return).

H. Turn the main disconnect switch to the OFF position.
   

8.0 ± 0.4 VDC    

Result: The voltage measurement is 8.0 ± 0.4 VDC. The ECM is operating correctly.

Repair: The supply wire is shorted to another wire in the harness or the supply wire is shorted to engine ground. Repair the supply wire.

Verify that the repair eliminated the problem.

Result: The voltage measurement is not 8.0 ± 0.4 VDC.

Repair: The ECM is not producing the correct supply voltage. There is a problem with the ECM. Replace the ECM. Refer to Troubleshooting, "Test ECM Mode".

Note: Before you consider replacing the ECM, consult with the Dealer Solutions Network (DSN) for assistance.

Verify that the repair eliminated the problem.
   

If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).

Caterpillar Information System:

3512C Marine Auxiliary Generator Set Engines with Dynamic Gas Blending Speed/Timing - Test
3512C HD and 3516C HD IPP Rental Power Modules Fuel Pressure Is Low - Diesel System
3512C Marine Auxiliary Generator Set Engines with Dynamic Gas Blending Starting - Test
3512C HD and 3516C HD IPP Rental Power Modules Fuel Filter Is Restricted
Thickness of the 102-5861 Thrust Plate Is Out of Specification on Certain 3400 Series Commercial and Machine Engines{1210} Thickness of the 102-5861 Thrust Plate Is Out of Specification on Certain 3400 Series Commercial and Machine Engines{1210}
DE Series Generator Set With Cat C4.4 Engine Belt Tensioner - Check - Poly V-Belt
DE Series Generator Set With Cat C4.4 Engine Belts - Inspect/Adjust/Replace
C3.3 and C4.4 Rental Generator Sets Alternator - Inspect
2014/03/28 New Software Is Used on Certain G3600 Petroleum Engines {1901, 1920}
C4.4 Marine Generator Set Water Pump - Inspect
C9.3 Marine Propulsion Engine Model View Illustrations
C9.3 Marine Propulsion Engine Safety Messages
3512C Marine Auxiliary Generator Set Engines with Dynamic Gas Blending Sensor Signal (PWM) - Test
3512C HD and 3516C HD IPP Rental Power Modules Intake Manifold Air Temperature Is High
DE Series Generator Set With Cat C4.4 Engine Battery - Replace
C7 Industrial Engine Air Shutoff - Test
DE Series Generator Set With Cat C4.4 Engine Engine - Clean
DE Series Generator Set With Cat C4.4 Engine Coolant Level - Check
DE Series Generator Set With Cat C4.4 Engine Engine Valve Lash - Check
DE Series Generator Set With Cat C4.4 Engine Battery or Battery Cable - Disconnect
DE Series Generator Set With Cat C4.4 Engine Generator - Dry
DE Series Generator Set With Cat C4.4 Engine Generator Load - Check
3512C Marine Auxiliary Generator Set Engines with Dynamic Gas Blending Sensor Signal (Analog, Passive) - Test
3512C Marine Auxiliary Generator Set Engines with Dynamic Gas Blending Sensor Signal (Analog, Active) - Test
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.