Alternator - Bosch K1/N1 Caterpillar


Capacitor - Test

Usage:

426C 1CR



Illustration 1g03221396

Discharging capacitor

(1) Capacitor mounting screw

(2) Capacitor lead

  1. Disconnect capacitor lead (2) from the terminal on the back of the alternator. Remove the plastic housing from lead (2) that surrounds the clip.

  1. Touch lead (2) to the capacitor mounting screw (1). This discharges the capacitor.

    Note: Each time this test is done, the capacitor must be discharged.




    Illustration 2g03221556

    Capacitor test

    (1) Capacitor mounting screw

    (2) Capacitor lead

  1. Put the multimeter on the 20M resistance (Ohms) scale. Connect one multimeter lead to capacitor lead (2). Touch the other lead to capacitor mounting screw (2) .

  1. There should be a very low resistance for a short period. Then resistance should stabilize above 100000 ohms (meter reading 0.10 or greater).

  1. If the reading is not correct, replace the capacitor.
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.