Show/hide table
|
Discharge air is hot and could cause property damage and/or personal injury. |
|
Note: Do not operate the unit below any overhang.
Show/hide table
|
|
|
Illustration 1 | g06389062 |
Typical flow of the exhaust
|
Show/hide table
|
|
|
Illustration 2 | g06389089 |
Top view of the package and the typical clearance around the package
|
The unit should have adequate clearance on all sides to allow proper air flow. Allow approximately 2 m (6.6 ft) of clearance on all sides.
- Place the unit in a stable position.
- Ensure that you use wheel chocks that are suitable for the trailer.
- Unfasten the tow vehicle before you operate the unit.
Show/hide table
|
NOTICE |
Ensure that the enclosure doors are closed and locked during generator set operation. Access to the generator set is prohibited during operation of the generator set. Access to the emergency stop push button cannot be obstructed or restricted. The emergency stop push button must be easily seen and the emergency stop push button must be readily accessible. The door latch cannot be lockable. The door latch cannot contain a provision for making the door latch lockable. |
|
Show/hide table
|
Failure to close doors when the unit is operating can result in doors opening and closing at a high rate of speed. Contact with the doors may cause personal injury or death. |
|
Show/hide table
|
|
|
Illustration 3 | g06389090 |
Typical chocking of the wheels and door latches
|