349E, 349F and 352F Excavators and 349E MHPU Mobile Hydraulic Power Unit Tool Control System Caterpillar


Solenoid Valve (Proportional Reducing) - Calibrate - Flow Limit Valves

Usage:

352F-VG A9J

Introduction

Negative flow control pressure flows to the regulators at the drive pump and the idler pump in order to control the output flow of the pumps. The proportional reducing valve for negative flow control regulates the amount of pilot pressure from the pilot pump and signal oil pressure from the main control valve that flows into the regulators of the main pumps. The proportional reducing valves for negative flow control are controlled by the machine ECM.

Required Tools



Illustration 1g01623868
Tooling (B)
198-4240 Digital Pressure Indicator Gp


Illustration 2g03626876
Tooling (D) (Flow meter tool layout)

Table 1
Required Tools 
Tool  Item  Part
Number 
Description  Qty 
198-4240  Digital Pressure Indicator Gp   
  B1  198-4234  Indicator 
B2 198-4239  Pressure Sensor
41,368 kPa (6,000 psi) 
B3 198-4236  Extension Cable 
D1  4C-9910  Portable hydraulic tester (flow meter) 
D2 6K-6307  O-Ring Seal 
D3 8C-9026  Adapter 
D4 7M-8485  O-Ring Seal 
D5 4C-6482  Fitting 
D6 4C-6481  Coupler 
D7 4C-8767  Coupling 
D8 5P-1010  Sleeve 
D9 5P-0201  Hose 
D10 1U-8293  Adapter 

Machine Preparation


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.

Dispose of all fluids according to local regulations and mandates.


  1. The following procedures must be completed before performing the calibration.

    • Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.

    • Calibrate the power shift pressure. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.

    • Calibrate the attachment valves. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Attachment Valves)" for the Tool Control System.

  2. Position the machine on level ground.

  3. Stop the engine.


    Illustration 3g03602396
    Stop valves for high-pressure oil delivery to the work tool (typical example)

  4. Close the stop valves that are mounted on each side of the stick in order to prevent oil loss.

  5. Release pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".


    Illustration 4g03642401
    Flow meter tool layout (stop valves on stick)
    (1) Left stop valve
    (2) Right stop valve

  6. Install the following tools in accordance with the flow meter tool layout. Refer to Illustration 4.

  7. Open the stop valves that are mounted on each side of the stick.


    Illustration 5g03626840
    Pump compartment
    (3) Pressure tap (delivery pressure for drive pump)
    (4) Pressure tap (delivery pressure for idler pump)

  8. Attach 41,368 kPa (6,000 psi) pressure sensors to pressure taps (3) and (4) for delivery pressure of the main pumps.

  9. Start the engine.

  10. Place the machine controls at the following settings: engine speed dial "10" and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for engine rpm settings.

  11. Increase the hydraulic oil temperature to 50° ± 10°C (122° ± 18°F).

Calibration Procedure

------ WARNING! ------

To prevent personal injury or equipment damage from failure of the hydraulic test equipment or associated circuit components because of blocked pump flow, make sure that the test equipment valves are fully open before starting the engine.


------ WARNING! ------

To prevent personal injury and/or equipment damage from failed lines or components while the hydraulic test equipment is returned to the open flow position, slowly open the hydraulic test equipment valve while monitoring the pump flow.

If pump flow does not increase as the valve is opened, shut the engine off and determine what is preventing the pump from upstroking.


Note: This procedure is typical for both proportional reducing valves for pump flow limit.

Use any of the following control inputs (A) shown in Illustration 6 and 7 to calibrate the flow limit valves.



Illustration 6g02333296
Electric Control Inputs for extension of the attachment control valves
(LJ) Left-hand joystick
(RJ) Right-hand joystick
(A) Thumb wheel (Forward)
(A) Switch
(EP) Electric foot pedal
(A) Pedal (Forward)
(FS) Foot switch
(A) Foot switch (ON)


Illustration 7g03082697
Hydraulic Control Inputs for extension of the attachment control valves
(HP) Hydraulic foot pedal
(A) Pedal (Forward)

  1. Select a work tool that will allow for two-way flow from two pumps. The Variable Relief Valve #1 (Parameter #9) pressure setting must be set to 40000 kPa (5802 psi) for the work tool within the monitor.

    Reference: Refer to Testing and Adjusting, "Work Tool - Select" for the Tool Control System.

    Reference: Refer to Testing and Adjusting, "Work Tool Parameter - Program" for the Tool Control System.

Monitor Procedure

The following procedure will allow the user to calibrate the flow limit valves using the monitor.

  1. Enter the service mode. Input the password "9992".


    Illustration 8g02276293

  2. Select "Main Pump Flow Limit" from the "Calibrations" menu.


    Illustration 9g02280293

  3. Select "NFC (Flow Meter Method)" for the appropriate valve from the "Main Pump Flow Limit" menu.

  4. Press the OK key in order to start the calibration. The engine RPM will automatically increase to the equivalence of engine speed dial 10.

  5. Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.


    Illustration 10g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve


    Illustration 11g02346336

    Note: Refer to Illustration 6 for the control input.

  6. Press and hold the control input for activation of the work tool to the FULL ON position during calibration.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".

  7. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  8. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 150 ± 2 L/min (39.6 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  9. Repeat Steps 7 and 8 until the flow meter reads 150 ± 2 L/min (39.6 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  10. Press the OK key.


    Illustration 12g02346337

    Note: Refer to Illustration 6 for the control input.

  11. Press and hold the control input for activation of the work tool to the FULL ON position during calibration.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".

  12. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  13. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 250 ± 2 L/min (66 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  14. Repeat Steps 12 and 13 until the flow meter reads 250 ± 2 L/min (66 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  15. Press the OK key.


    Illustration 13g02281293

  16. If calibration was successful and no errors occurred, the display will indicate that the calibration is complete.


    Illustration 14g02281435

  17. The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.

Test Procedure

Confirm the calibration using the following procedure and specifications. Refer to Table 2 for the load pressure and flow specifications.

    Note: This procedure is typical for both proportional reducing valves for pump flow limit.

  1. Enter the service mode.


    Illustration 15g02283177

  2. Select "Main Pump Flow Limit" from the "Device Test" menu.


    Illustration 16g02283214

  3. Select the test for the appropriate valve from the "Main Pump Flow Limit" menu.

  4. Press the OK key in order to start the test.

  5. Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.


    Illustration 17g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve


    Illustration 18g02283194

  6. Set the main pump pressure using load valve (5) on the flow meter. Use the arrows to adjust the flow. Refer to Table 2 for the load pressures and flow specifications.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump Outlet Pressures", and "Pump NFC Pressures".

Table 2
"Solenoid Valve (Proportional Reducing) - Calibrate (Flow Limit Valves)" 
Date  Machine Serial Number 
Machine Settings  Engine Speed 
Engine speed dial "10"
AEC switch OFF
 
Flow set using Device Test in Service Mode  Load pressure applied with flow meter 
12000 kPa (1740 psi) 16000 kPa (2321 psi) 20000 kPa (2901 psi) 
Flow Specifications
One Pump Flow  150 L/min (37.0 US gpm)  142 to 158 L/min (37.5 to 41.7 US gpm)  142 to 158 L/min (37.5 to 41.7 US gpm)  142 to 158 L/min (37.5 to 41.7 US gpm) 
 
200 L/min (52.8 US gpm) 190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm) 
   
250 L/min (66.0 US gpm) 237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm) 
   
Two Pump Flow  200 L/min (52.8 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm) 
 
250 L/min (66.0 US gpm) 237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm) 
   
300 L/min (79.3 US gpm) 285 to 315 L/min (75.3 to 83.2 US gpm)  285 to 315 L/min (75.3 to 83.2 US gpm)  285 to 315 L/min (75.3 to 83.2 US gpm) 
   

Cat Electronic Technician Procedure

The following procedure will allow the user to calibrate the flow limit valves using the Cat Electronic Technician.



    Illustration 19g02713701
    Diagnostic connector for Cat Electronic Technician

  1. Connect the Cat Electronic Technician to the diagnostic connector located behind the seat on the left side of the cab.


    Illustration 20g02713758

  2. Start Cat Electronic Technician.


    Illustration 21g02713761

  3. Select the ECM for "Machine Control".


    Illustration 22g02723808

  4. Select "Calibrations" from the "Service" menu.


    Illustration 23g02724846

  5. Highlight "PRV - Main Pump Flow Limitation Pressure Calibration" and click on the "Start" button in the lower left corner of the screen.


    Illustration 24g02724848

  6. Select the flow limit valves to calibrate and press the "Begin" button.


    Illustration 25g02724853

  7. Follow the instructions on the screen. Press "Next" button to continue through to the next step.


    Illustration 26g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve

  8. Set the main pump pressure using load valve (5) on the flow meter. Use the arrows to adjust the flow.

  9. Press and hold the control input for activation of the work tool to the FULL ON position during calibration.

  10. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  11. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 150 ± 2 L/min (39.6 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  12. Repeat Steps 10 and 11 until the flow meter reads 150 ± 2 L/min (39.6 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  13. Press the "NEXT" button.

  14. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  15. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 250 ± 2 L/min (66 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  16. Repeat Steps 14 and 15 until the flow meter reads 250 ± 2 L/min (66 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  17. Press the "NEXT" button.

  18. If the calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Press the "Finish" button to exit or move on to the next calibration.

  19. If the calibration failed, the calibration is not saved. Press the "Restart" button to try the calibration again or press the "Finish" button to exit or move on to the next calibration.

Test Procedure

Confirm the calibration using the following procedure and specifications. Refer to Table 2 for the load pressure and flow specifications.



    Illustration 27g02726867

  1. Select "Diagnostic Tests" from the "Diagnostics" menu.


    Illustration 28g02726886

  2. Highlight "Main Pump Flow Limitation Pressure Test" and click on the "Start" button in the lower left corner of the screen.


    Illustration 29g02726938

  3. Select the test and press the "Begin" button.


    Illustration 30g02726940

  4. Follow the instructions on the screen. Press "Start" button in the lower left corner to begin the test.


    Illustration 31g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve

  5. Set the main pump pressure using load valve (5) on the flow meter. Use the arrows to adjust the flow. Refer to Table 3 for the load pressures and flow specifications.

Table 3
"Solenoid Valve (Proportional Reducing) - Calibrate (Flow Limit Valves)" 
Date  Machine Serial Number 
Machine Settings  Engine Speed 
Engine speed dial "10"
AEC switch OFF
 
Flow set using Diagnostic Test in Cat ET  Load pressure applied with flow meter 
12000 kPa (1740 psi) 16000 kPa (2321 psi) 20000 kPa (2901 psi) 
Flow Specifications
One Pump Flow  150 L/min (37.0 US gpm)  142 to 158 L/min (37.5 to 41.7 US gpm)  142 to 158 L/min (37.5 to 41.7 US gpm)  142 to 158 L/min (37.5 to 41.7 US gpm) 
 
200 L/min (52.8 US gpm) 190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm) 
   
250 L/min (66.0 US gpm) 237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm) 
   
Two Pump Flow  200 L/min (52.8 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm) 
 
250 L/min (66.0 US gpm) 237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm)  237 to 263 L/min (62.6 to 69.5 US gpm) 
   
300 L/min (79.3 US gpm) 285 to 315 L/min (75.3 to 83.2 US gpm)  285 to 315 L/min (75.3 to 83.2 US gpm)  285 to 315 L/min (75.3 to 83.2 US gpm) 
   

Caterpillar Information System:

C13 Tier 4 Final Engines Air Cleaner
C13 Tier 4 Final Engines Air Cleaner
UPSB220 Uninterruptible Power Supply Single UPS Startup and Shutdown
UPSB220 Uninterruptible Power Supply Single UPS Connection
UPSB220 Uninterruptible Power Supply Parallel UPS Startup and Shutdown
UPSB220 Uninterruptible Power Supply Parallel UPS Connection
UPSB220 Uninterruptible Power Supply Modes Of Operation
UPSB220 Uninterruptible Power Supply Maintenance Interval Schedule
UPSB220 Uninterruptible Power Supply Electrical Specification
UPSB220 Uninterruptible Power Supply Component Location
UPSB220 Uninterruptible Power Supply Circuit Breaker Recommendation
UPSB220 Uninterruptible Power Supply Cable Routing
C27 and C32 Engines for Caterpillar Built Machines Piston and Rings
XQP150 Rental Generator Set Belts - Inspect/Adjust/Replace
C7.1 (Mech) Industrial Engine Engine Air Cleaner Element (Dual Element) - Inspect/Clean/Replace
C7.1 (Mech) Industrial Engine Engine Air Cleaner Element (Single Element) - Inspect/Clean/Replace
C3.4B Industrial Engine Engine Air Cleaner Element (Single Element) - Inspect/Clean/Replace
3516B Marine Auxiliary Engine Cat Data Link - Test
C27 and C32 Engines Exhaust Elbow - Remove and Install - Clean Emissions Module Inlet
C15 and C18 Industrial Engines Pistons and Connecting Rods - Remove and Install
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Pressure Switch (Refrigerant Pressure Cutoff)
2010/12/08 An Improvement has been Made to Reduce the Amount of Radial Play of the Front Linkage Pin on Certain Excavators {6501, 6502, 6513}
C15 and C18 Engines for Caterpillar Built Machines Pressure Sensor (Cooled Exhaust Gas) - Remove and Install - Differential Pressure
C15 and C18 Engines for Caterpillar Built Machines Pressure Sensor (Cooled Exhaust Gas) - Remove and Install - Outlet Pressure
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.