349F and 352F Excavators Hydraulic System Caterpillar


Pump Control (Negative Flow) - Test

Usage:

352F-VG A9J

Specification

Table 1
"Pump Control (Negative Flow) - Test"    
Machine Settings     Pump Flow Limit Pressure     Power Shift Pressure     Measuring Point     Engine Speed    
2500 kPa (363 psi)
2000 kPa (290 psi)    

6900 kPa (1000 psi)    
Engine speed dial "10"
AEC switch OFF
(1800 rpm)    
Negative Flow Control    
Oil Temperature °C (°F)     Drive pump        
Idler pump    
Engine Speed (rpm)     Drive pump        
Idler pump    
Flow measured liter/min (US gpm)     Drive pump        
Idler pump    
Flow corrected liter/min (US gpm)     Drive pump        
Idler pump    
Specification for negative flow rate liter/min (US gpm)    
192 ± 25 L/min (50.7 ± 6.6 US gpm)    



Illustration 1g03120777

Pressure/Flow characteristic curve

Note: Specifications for flow rates are based on an engine speed of 1800 rpm. To get more accurate test results, measured flow should be corrected with the following calculation.

Table 2
Corrected flow     =     Measured flow x 1800 rpm    
Measured rpm

Flow measurements must be done only during pressure rise.

Introduction

This test measures individual pump flow at the pump while a fixed negative flow control pressure is sent to the main pump regulator. Each pump is tested individually for an output flow rate at a specified delivery pressure and a specified negative flow control pressure.

Preliminary Test

  • Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust"

  • Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.

  • Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Negative Flow Control)"

Required Tools




Illustration 2g02571852

Tooling (A) 198-4240 Digital Pressure Indicator Gp




Illustration 3g02535237

Tooling (C)




Illustration 4g02146945

Tooling (D) (Flow meter tool layout)

Table 3
Tool     Item     Qty     Part
Number    
Description    
A         198-4240     Digital Pressure Indicator Gp    
    A1     1     198-4234     Indicator    
A2 2     198-4237     Pressure Sensor

3447 kPa (500 psi)    
A2 2     198-4239     Pressure Sensor

41,368 kPa (6,000 psi)    
A3 4     198-4236     Extension Cable    
C         348-5430     Multi-Tool Gp    
    C1     1     285-0908     Multi-Tool    
C2 1     6V-2198     Cable As    
C3 1     9U-5140     Photo Pickup    
C4 1     6V-3137     Base    
C5 1     1U-6605     Reflective Tape    
C6 1     6V-3138     Extension    
D     D1     1     436-8662     Portable hydraulic tester (flow meter)    
D2 2     6K-6307     O-Ring Seal    
D3 2     8C-9026     Adapter    
D4 9     7M-8485     O-Ring Seal    
D5 4     4C-6482     Fitting    
D6 4     4C-6481     Coupler    
D7 4     4C-8767     Coupling    
D8 4     5P-1010     Sleeve    
D9 2     5P-0201     Hose    
D10 1     9S-4191     O-Ring Plug    
D11 1     3J-1907     O-Ring Seal    
D12 1     1U-8303     Fitting    
D13 4     8T-4184     Bolt    
D14 4     8T-4223     Hard Washer    
D15 2     1P-5767     Half Flange    
D16 1     1U-8293     Adapter    
D17 1     1P-3704     Rectangular Seal    
D18 1     7I-7133     Blocking Cover    
D19 1     124-8333     Elbow    
D20 2     5K-9090     O-Ring Seal    
D21 1     6V-9840     Swivel Tee    
F     1     311-1362     Vacuum Cap    

ReferenceRefer to Tool Operating Manual, NEHS1087 for operating instructions for the 348-5430 Multi-Tool Gp .

Note: Use Software License Card, NETG5049 with part number 348-5430 Multi-Tool Gp .

Machine Preparation


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.

Dispose of all fluids according to local regulations and mandates.


Note: Perform the test for the drive pump and the test for the idler pump one at a time.




Illustration 5g02405217

Pump compartment

(1) Pressure tap (delivery pressure for drive pump)

(2) Pressure tap (delivery pressure for idler pump)

(3) Pressure tap (power shift pressure)

(4) Delivery line for drive pump

(5) Delivery line for idler pump

(6) Negative flow control line (drive pump)

(7) Negative flow control line (idler pump)

  1. Position the machine on level ground.

  1. Stop the engine.

  1. Release pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".

  1. Attach 311-1362 Vacuum Cap onto the hydraulic tank. Attach an air supply hose onto the assembly. Apply 276 to 414 kPa (40 to 60 psi). This procedure will pull a vacuum on the hydraulic system.



    Illustration 6g02149462

    Flow meter tool layout

    Tooling (D)

    (4) Delivery line for drive pump

    (5) Delivery line for idler pump

    (8) Bolt

    (9) Washer

    (10) Half flange

    (11) Seal

    (12) Makeup line

    (13) Seal

    (14) Elbow

  1. Install the following tools in accordance with the flow meter tool layout. Refer to Illustration 6.

    1. Disconnect delivery line (4) from the drive pump or delivery line (5) from the idler pump.

    1. Install seal (11) , half flanges (10) , and blocking cover (D18) to the end of the delivery line with bolts (8) and washers (9) .

    1. Assemble and install seal (D17) , adapter (D16) , seals (D4) , fitting (D12) , seal (D11) , plug (D10) , and fitting (D5) on the drive pump by using half flanges (D15) , bolts (D13) , and washers (D14) .



      Illustration 7g02149639

      Swing motor (top view)

      (12) Makeup line

      (13) Seal

      (14) Tee

    1. Disconnect makeup line (12) from tee (14) at the right swing motor.

    1. Assemble and install seals (D20) , tee (D21) , elbow (D19) , seal (D4) , and fitting (D5) to tee (14) at the swing motor.

    1. Connect seal (13) and makeup line (12) to tee (D21) .

  1. Remove 311-1362 Vacuum Cap and install the filler plug for the hydraulic tank.

  1. Connect portable hydraulic tester (D) and test hoses between coupling assembly at the drive pump or the idler pump and coupling assembly at the swing motor.

  1. Attach a 41,368 kPa (6,000 psi) pressure sensor to pressure tap (1) for delivery pressure of the drive pump. Attach a 41,368 kPa (6,000 psi) pressure sensor to pressure tap (2) for delivery pressure of the idler pump.



    Illustration 8g02404719

    Pump compartment

    (6) Negative flow control line (drive pump)

    (7) Negative flow control line (idler pump)

    (15) Pressure tap (negative flow for drive pump)

    (16) Pressure tap (negative flow for idler pump)

  1. Attach a 3447 kPa (500 psi) pressure sensor to pressure tap (15) for negative flow control pressure for the drive pump. Attach a 3447 kPa (500 psi) pressure sensor to pressure tap (16) for negative flow control pressure for the idler pump.

  1. Install tooling (C) on the engine to monitor engine speed.

Test Procedure

Note: Perform the test for the drive pump and the test for the idler pump one at a time.

------ WARNING! ------

To prevent personal injury or equipment damage from failure of the hydraulic test equipment or associated circuit components because of blocked pump flow, make sure that the test equipment valves are fully open before starting the engine.

----------------------

------ WARNING! ------

To prevent personal injury and/or equipment damage from failed lines or components while the hydraulic test equipment is returned to the open flow position, slowly open the hydraulic test equipment valve while monitoring the pump flow.

If pump flow does not increase as the valve is opened, shut the engine off and determine what is preventing the pump from upstroking.

----------------------

  1. Start the engine.

  1. Increase the hydraulic oil temperature to 55° ± 5°C (131° ± 9°F).

  1. Place the machine controls at the following settings: engine speed dial "10" and AEC switch OFF. Refer to

  1. Enter the service mode.

    1. Input the password "9992".

    1. Select "Override Parameters".

  1. Set the engine speed to 1800 rpm.

  1. Override "Pump Flow Limit Pressure" to 2500 kPa (363 psi). Confirm the pump flow limit pressure measurement at pressure tap (15) or pressure tap (16) .

    Note: Override pump flow limit pressure back to 4000 kPa (580 psi) before attempting to enter a second override value.

  1. Override power shift pressure to 2000 kPa (290 psi). Confirm the power shift pressure setting at pressure tap (3) .

    Note: Override power shift pressure back to 4000 kPa (580 psi) before attempting to enter a second override value.




    Illustration 9g02599896

    Portable hydraulic tester (flow meter)

    (D1) Portable hydraulic tester (flow meter)

    (17) Valve

  1. Turn valve (17) on the portable hydraulic tester clockwise until pump pressure is at 6900 kPa (1000 psi). Use the pressure sensor at pressure tap (1) to monitor the delivery pressure of the drive pump or use pressure tap (2) to monitor the delivery pressure of the idler pump.

    Note: In order to perform flow measurements for either one of the pumps, the other pump must not be under load.

Caterpillar Information System:

C9.3 Engines for Caterpillar Built Machines Vibration Damper and Pulley - Remove and Install
CB22B, CB24B, CB32B and CC24B Utility Compactors Fuel System - Prime
C4.4 Industrial Engine Electronic Control System
C4.4 Industrial Engine Power Sources
C4.4 Industrial Engine Fuel Injection
C4.4 Industrial Engine Introduction
C4.4 Industrial Engine Lubrication System
Bench Test Procedure for Hydraulic Piston Pumps {0784, 5070} Bench Test Procedure for Hydraulic Piston Pumps {0784, 5070}
C4.4 Industrial Engine Basic Engine
C4.4 Industrial Engine Cooling System
C4.4 Industrial Engine Air Inlet and Exhaust System - Series Turbochargers
Replacement Procedure for Power Conductor Braids With New Silicone Cables{1408, 4460} Replacement Procedure for Power Conductor Braids With New Silicone Cables{1408, 4460}
C27 and C32 Engines for Caterpillar Built Machines Exhaust Cooler (NRS) - Clean
2010/05/31 A New Spark Plug Is Used in G3600 Engines {1550, 1555}
C9.3 Engines for Caterpillar Built Machines Front Cover - Remove and Install
2010/05/06 Changes in Performance After Replacing High Hour Fuel Injectors on Certain 3412E Marine Engines {1251, 1254, 1290, 1713}
C4.4 Industrial Engine Crankshaft Pulley - Check
C6.6 Industrial Engine Fuel Priming Pump - Remove and Install - Electric Fuel Lift Pump (EFLP)
C6.6 Industrial Engine Fuel Filter Base - Remove and Install - Single Secondary Fuel Filter
C6.6 Industrial Engine Fuel Manifold (Rail) - Remove and Install
C6.6 Industrial Engine Fuel Injection Lines - Remove
G3520E Generator Set Engines Air Lines
C6.6 Industrial Engine Fuel Injection Lines - Install
C6.6 Industrial Engine Inlet Air Control - Remove - NRS Inlet Air Mixer
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.