Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Caterpillar


Programmable Kilowatt Level Output

Usage:

C32 SXC
The programmable kilowatt level output is a feature that can be enabled by programming setpoint P138. The programmable kilowatt level output can be disabled by programming setpoint P138. The programmable kilowatt level output draws a maximum of 100 mA when the programmable kilowatt level output is active. When the programmable kilowatt level output is inactive, the programmable kilowatt level output is pulled high to ("BATT+"). The programmable kilowatt level output (GSC+P connector contact 34) will be activated whenever the total power output of the generator passes the programmed threshold (setpoint P139). This threshold can be programmed from 0 percent to 110 percent of the nameplate power (setpoint P030). A time delay can be programmed from 0 seconds to 120 seconds (setpoint P140).

Once the programmable kilowatt level output is activated, the programmable kilowatt level output will be deactivated when the total power output of the generator drops below a programmed threshold (setpoint P141). The programmed threshold is different from the activation threshold. The threshold can be programmed from 0 percent to 110 percent of the total power rating of the generator. A deactivation time delay can be programmed from 0 seconds to 120 seconds (setpoint P140).

Refer to System Operation, "Engine/Generator Programming OP5-0" for more information.

Note: The GSC+P diagnoses faults in the programmable kilowatt level output circuit. Refer to Testing And Adjusting, "Diagnostic Codes".

Caterpillar Information System:

Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Programmable Spare Output
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Programmable Spare Relay Outputs
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Diagnostic Codes
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) SP Fault Codes
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) AL Fault Codes
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Fault Description
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Coolant Level - Test
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Parallel Setpoint Tuning OP-11
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) AC Offset Adjustment OP10
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Engine Setpoint Verification OP9
3516C Generator Set Engine Engine Control Switch - Test
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Voltmeter/Ammeter Programming OP8
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module CAN Data Link - Test
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Alarm Modules
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Injector Solenoid - Test
C7 and C9 On-Highway Engines Solenoid Valve - Test
3516C Generator Set Engine Speed/Timing - Test
3500B Locomotive Engines Belt Tension Chart
2007/12/24 Oil Suction Tube {1302}
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Alarm Module Control (Custom)
2008/04/21 A New Wire Assembly is Used to Ground the Enclosure for the ECM {1901, 7556}
3500B Engines for Caterpillar Built Power Modules with the ADEM 3 Electronic Control Module Cat Data Link - Test
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Customer Interface Module
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) System Communication Module (Customer)
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.