NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Dispose of all fluids according to local regulations and mandates. |
- Drain the coolant from the cooling system to a level below the water temperature regulator, into a suitable container for storage or for disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct draining procedure.
- Loosen the hose clamps from the upper radiator hose and disconnect the upper radiator hose from water temperature regulator housing (2).
Show/hide table
Illustration 1 g01343959 Typical example - Remove bolts (1) from water temperature regulator housing (2).
- Remove water temperature regulator housing (2) from the cylinder head.
Note: Note the orientation of the water temperature regulator housing.
Show/hide tableIllustration 2 g01430625 Typical example - Remove O-ring seal (3) (not shown) from water temperature regulator housing (2).
Required Tools | |||
Tool | Part Number | Part Description | Qty |
A | 1U-6396 | O-Ring Assembly Compound | 1 |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Ensure that all components of water temperature regulator are clean and free of wear or damage. Check the water temperature regulator for correct operation. Refer to Systems Operation, Testing and Adjusting, "Water Temperature Regulator - Test" for the procedure to test the water temperature regulator. If any components of the water temperature regulator are worn or damaged, the complete assembly must be replaced.
- The bore in the cylinder head for the water temperature regulator should be clean and free from damage.
Show/hide table
Illustration 3 g01343960 Typical example - If the original water temperature regulator housing is installed, position a new O-ring seal (3) into the groove in water temperature regulator housing (2).
A new water temperature regulator housing is supplied with a new O-ring seal.
- Use Tooling (A) to lubricate the new O-ring seal.
- Install water temperature regulator housing (2) to the cylinder head.
Note: Ensure the correct orientation of the water temperature regulator housing.
Show/hide tableIllustration 4 g01343959 Typical example - Install bolts (1). Tighten the bolts to a torque of
22 N·m (16 lb ft) . - Connect the upper radiator hose and tighten the hose clamps.
- Fill the cooling system to the correct level. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the correct procedure.