1977/07/04 Caterpillar


New Procedure For Calibration Of 1P3060 Pyrometer Group{0653,1050}

Usage:


Special Instruction Form GMG00697-02, "Using the 1P3060 Pyrometer Group", gives information needed to test, do regular maintenance and make some repairs on this tool group.

The FT1012 and FT1013 Calibrated Circuits shown on Page 9 of this Special Instruction are not correct and must not be used. These tools were to be used to check the reading accuracy of the pyrometer.

A new procedure must be used for this purpose. An explanation of this procedure will be part of a new special instruction which will soon be available. The new procedure permits the pyrometer scale to be checked at 800°F, 1200°F and 1600°F. To do this, a controlled voltage is sent to the pyrometer across a 3 to 4 ohm resistance over a new calibration circuit. Example calibration points, input voltage and temperature, are shown in a chart. If at any one of these points the pyrometer reading error is more than ± 16°F, the unit must be sent to Alnor Instrument Co. for repair. The address shown in Special Instruction Form GMG00697-02 is wrong. Send the pyrometer units to:

Alnor Instrument Co.
Repair Dept.
7300 North Natchez Ave.
Niles, Illinois 60648

If you do not have the equipment to check pyrometer accuracy, most electronic repair shops can normally make these checks in less than half an hour.

New Calibration Procedure to Check Reading Accuracy of the 1P3060 Pyrometer Group:

Only use the calibration circuit and information that follows to check the pyrometer reading accuracy:

CIRCUIT CONDITIONS
1. All resistors are 1/4 watt, 20%.
2. Digital voltmeter (DVM) has a maximum resolution of 100 microvolts (10 microvolts minimum) and not less than 0.1% accuracy.
3. 12 VDC can be a 12 volt automotive battery or a bench power supply.
4. R1 is a carbon potentiometer (volume control).

NOTE: The circuit does not have to be exact, but the voltage produced (made) across the resistance must be known.

The input power (12 VDC) is decreased to millivolts when sent across the three parallel resistors. This is similar to a thermocouple output with 3.33 ohms resistance. The potentiometer (R1) is adjusted until the digital voltmeter (DVM) reads each of the values in the chart that follows. The pyrometer must read the temperature opposite, within ± 16°F.

NOTE: If a bench power supply is used, the potentiometer (R1) can be zero ohms and the power supply voltage can be adjusted to give the necessary calibration voltages.


New calibrator circuit.

Caterpillar Information System:

1977/07/04 New Seal For Crankshaft{1161}
1977/07/04 Use New Procedure To Tighten Flywheel Housing Bolts{1157,1201}
1977/07/04 Tools To Hone (Machine) Cylinder Liners Are Available To Permit The Use Of Used Cylinder Liners With New Style Pistons{0664,1214,1216}
1977/06/27 Service Tools For Low Emission Truck Engines With EGR{0650,1059,1080}
1977/06/27 New Aftercooler Housings And Covers Have Improved Design{1063}
1977/06/27 Correct Rebuild Kits Must Be Used For Repair Of Earlier And Later Water Pumps{1361}
1977/06/27 More Of The Oversize (Larger) Cast Iron Seal Rings Are Available For Clutch Housings And Clutch Pistons{3169,3170}
1977/06/20 Socket For Removal And Installation Of Fuel Injection Pump Bushings is Now Stronger{0612,1253}
1977/06/20 5P7333 Tool Group Available For The Repair Of Loose Bridge Dowels On Cylinder Heads{0663,1101}
1977/06/13 New Adapter Group For Use With Fuel Injection Test Bench{0652}
1977/06/06 5P7386 Seal Driver For Hydraulic Pumps And Swing Motor{0622,5058,5070}
1977/06/06 Water Pump Has Stronger Pulley{1361}
1977/07/11 Tools To Install Crankshaft Seal And Wear Sleeve{1160,1161,0622}
1977/07/11 Some Earlier Vickers Hydraulic Pump Groups Are Not Available For Parts Service--Some Modification Is Needed To Install Replacement Pump Groups{5055}
1977/07/11 Baffle Added To Water Pump Cover To Send Coolant In Bypass Line Directly Into The Water Pump{1361}
1977/07/11 New Adjustment Pin And Valve Seal Used In Fuel Ratio Control{1278}
1977/07/11 Safety Vent Caps For Caterpillar Batteries{1401}
1977/07/11 New Component Code List For Use In The Service Information Retrieval System{0331,0374}
1977/07/11 Heat Absorbing Material Aids And Protects Surface Areas Being Welded Or Heated{0680}
1977/07/11 New Inserts To Repair Cylinder Liner Seats On D353 Engine Blocks{1201,1216,1217,0663,0653}
1977/08/08 Correct Adjustment Of Fuel Shut-Off Solenoid Shaft Can Prevent Failures{1259}
1977/08/08 New Vickers Pump Design{5055}
1977/08/08 Larger Boss Used In Cylinder Block So Bolt Hole Will Not Be Drilled Into Coolant Passage{1201,1350}
1977/08/08 Spacers Added To Alternator Group To Improve The Mounting{1405}