To help prevent excessive engine wear, use the following guidelines:
- Complete all of the lubrication recommendations that are listed in this Operation and Maintenance Manual, "Maintenance Interval Schedule" (Maintenance Section).
- If freezing temperatures are expected, check the cooling system for adequate protection against freezing. See this Operation and Maintenance Manual, "Refill Capacities and Recommendations" (Maintenance Section).
- Engines with aftercoolers require the draining of the aftercoolers for preparation of storage or transport.
NOTICE |
---|
Failure to drain the aftercoolers may result in damage to the aftercoolers in a freezing environment during storage or transportation. |
Follow the recommended procedure for draining the aftercoolers.
- Remove the aftercooler drain plugs. Allow the coolant to drain.
- Clean the aftercooler drain plugs. Install the aftercooler drain plugs.
NOTICE |
---|
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. |
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer ServiceTools:
Outside U.S.A. 309-578-7372Inside U.S.A. 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
If an engine is out of operation and if use of the engine is not planned, special precautions should be made. If the engine will be stored for more than one month, a complete protection procedure is recommended.
For more detailed information on engine storage, see Special Instruction, SEHS9031, "Storage Procedure For Caterpillar Products".
Your Caterpillar dealer can assist in preparing the engine for extended storage periods.