PL61 Pipelayer and D6K Track-Type Tractor Caterpillar


MID 039 - CID 0583 - FMI 06

Usage:

D6K LGP DHA
Conditions Which Generate This Code:


Illustration 1g01440322

Schematic of the boom raise solenoid

This diagnostic code is associated with the boom raise solenoid. The FMI 06 means that the ECM has detected that the current for the solenoid circuit s above normal.

Conditions that could causes this diagnostic code to be activated are:

  • The energize circuit of the solenoid is shorted to a ground source.

  • The solenoid has failed.

  • The ECM has failed. This is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

Note: The resistance of the solenoid coil should be 27 ± 1.4 ohms at 20 °C (68.0 °F).

Test Step 1. CHECK THE SOLENOID

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. Observe the status of the diagnostic code.

  1. Disconnect the solenoid with the active diagnostic code from the machine harness.

Expected Result:

The active CID 0583 FMI 06 diagnsotic code changes to a CID 0583 FMI 05 diagnostic code when the solenoid is disconnected.

Results:

  • YES - The active CID 0583 FMI 06 diagnostic code changes to a CID 0583 FMI 05 diagnostic code when the solenoid is disconnected. The solenoid circuit in the machine harness is correct.

    Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.

    STOP

  • NO - The CID 0583 FMI 06 diagnostic code remains active. Disconnecting the solenoid did not change the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.

Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND

The solenoid remains disconnected from the machine harness.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness ECM connectors J1 and J2 from the ECM.

  1. At the machine harness ECM connectors, measure the resistance from the signal contact J1-61 (wire M928-BU) to frame ground. Measure the resistance from the signal contact J1-61 (wire M928-BU) to all of the other contacts that are used in J1 and J2 ECM connectors.

  1. While observing the multimeter resistance measurements, wiggle the machine harness connectors for the ECM and the solenoid. Gently pull on the wires and move the wires around.

Expected Result:

Each resistance measurement is greater than 5000 ohms at all times during the manipulation of the harness and connectors.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - One or more of the resistance measurements is less than 5000 ohms. The resistance measurement is indicating that a short is present in the machine harness. The short is between wire M928-BU and either frame ground or the circuit with the low resistance measurement.

    Repair: For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the sensor circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the CID 0583 FMI 06 diagnostic code.

Expected Result:

The CID 0583 FMI 06 diagnostic code is still active.

Results:

  • YES - The CID 0583 FMI 06diagnostic code is still active. The diagnostic code has not been corrected.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again. If the cause of the problem is not found, the ECM may have failed.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0583 FMI 06 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 0583 - FMI 05
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 0583 - FMI 03
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 00
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 13
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 08
992K Wheel Loader and 854K Wheel Dozer Braking System Parking Brake - Manual Release
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 01
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 00
844K and 854K Wheel Dozers and 990K, 992K, 993K, 994F and 994H Wheel Loaders Powered Access Stairway MID 082 - CID 0350 - FMI 13
992K Wheel Loader and 854K Wheel Dozer Braking System Parking Brake System Pressure - Test
Procedure to Install the New Fuel Manifold and the Fuel Lines on Certain Caterpillar Machines{1250, 1251, 1261, 1274, 1702} Procedure to Install the New Fuel Manifold and the Fuel Lines on Certain Caterpillar Machines{1250, 1251, 1261, 1274, 1702}
992K Wheel Loader and 854K Wheel Dozer Braking System Service Brake Discs - Check
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 0583 - FMI 13
992K Wheel Loader and 854K Wheel Dozer Braking System Brake Control Valve (Service)
2008/02/04 Improved Wiring Groups are Used {1403, 1408}
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 01
2008/03/17 The Elevator Frame Has Been Improved {6210, 6241}
993K Wheel Loader Machine Systems Lift Cylinder - Remove and Install
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 03
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 04
992K Wheel Loader Electrohydraulic System Hydraulic System Operation
993K Wheel Loader Machine Systems Steering Neutralizer Valve - Remove and Install
992K Wheel Loader Electrohydraulic System MID 082 - CID 0353 - FMI 00
993K Wheel Loader Machine Systems Relief Valve (Steering Pilot) - Remove
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.