PL61 Pipelayer and D6K Track-Type Tractor Caterpillar


MID 039 - CID 0583 - FMI 03

Usage:

D6K LGP DHA
Conditions Which Generate This Code:


Illustration 1g01440322

Schematic of the Boom Raise Solenoid

Note: FMI 03 is a warning level 2.

This diagnostic code is associated with the boom raise solenoid. The FMI 03 means that the ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.

Conditions that can cause this diagnostic code to activate:

  • The energize circuit of the solenoid is shorted to another voltage source.

  • The ECM has failed. This is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT

  1. Turn the disconnect switch and the key start switch to the OFF position.

  1. Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 and J2 from the ECM.

  1. At the machine harness ECM connectors, measure the resistance from contact J1-61 (wire M928-BU) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.

  • NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness.

    Repair: The short is between wire M928-BU and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace the machine harness.

    STOP

Test Step 2. CHECK THE OPERATION OF THE ECM

The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.

  1. At the machine harness connector J2 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire M928-BU and socket at contact J1-61 from the harness connector.

  1. Reconnect the machine harness J1 and J2 connectors to the ECM.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Observe the status of the active CID 0583 FMI 03 diagnostic code.

Expected Result:

The CID 0583 FMI 03 diagnostic code is no longer active. A CID 0583 FMI 05 diagnostic code is now active.

Results:

  • YES - The CID 0583 FMI 03 diagnostic code is no longer active. A CID 0583 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit.

    Reinstall the disconnected solenoid energize wire back into the correct space in the ECM connector before proceeding to the next test step.

    Proceed to Test Step 3.

  • NO - The CID 0583 FMI 03 diagnostic code remains active. The status of the active diagnostic code did not change when the solenoid energize wire was disconnected from the ECM.

    Repair: The ECM has not responded correctly to the open condition in the solenoid circuit. The operation of the ECM is not correct.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated. Make sure that the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Determine if the CID 0583 FMI 03 diagnostic code is active.

Expected Result:

The CID CID 0583 FMI 03 diagnostic code is active.

Results:

  • YES - The CID 0583 FMI 03 diagnostic code remains active.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect intermittent shorts or opens in the machine wiring harness.If the problem remains, the ECM may have failed. This is unlikely because the ECM detected the open circuit condition in the solenoid circuit and activated the FMI 05 diagnostic code when the solenoid energize wire was disconnected.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0583 FMI 03 code is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 00
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 13
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 08
992K Wheel Loader and 854K Wheel Dozer Braking System Parking Brake - Manual Release
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 01
992K Wheel Loader Electrohydraulic System MID 082 - CID 0351 - FMI 00
844K and 854K Wheel Dozers and 990K, 992K, 993K, 994F and 994H Wheel Loaders Powered Access Stairway MID 082 - CID 0350 - FMI 13
992K Wheel Loader and 854K Wheel Dozer Braking System Parking Brake System Pressure - Test
Procedure to Install the New Fuel Manifold and the Fuel Lines on Certain Caterpillar Machines{1250, 1251, 1261, 1274, 1702} Procedure to Install the New Fuel Manifold and the Fuel Lines on Certain Caterpillar Machines{1250, 1251, 1261, 1274, 1702}
992K Wheel Loader and 854K Wheel Dozer Braking System Service Brake Discs - Check
844K and 854K Wheel Dozers and 990K, 992K, 993K, 994F and 994H Wheel Loaders Powered Access Stairway MID 082 - CID 0350 - FMI 08
844K and 854K Wheel Dozers and 990K, 992K, 993K, 994F and 994H Wheel Loaders Powered Access Stairway MID 082 - CID 0350 - FMI 01
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 0583 - FMI 05
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 0583 - FMI 06
PL61 Pipelayer and D6K Track-Type Tractor MID 039 - CID 0583 - FMI 13
992K Wheel Loader and 854K Wheel Dozer Braking System Brake Control Valve (Service)
2008/02/04 Improved Wiring Groups are Used {1403, 1408}
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 01
2008/03/17 The Elevator Frame Has Been Improved {6210, 6241}
993K Wheel Loader Machine Systems Lift Cylinder - Remove and Install
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 03
992K Wheel Loader Electrohydraulic System MID 082 - CID 0352 - FMI 04
992K Wheel Loader Electrohydraulic System Hydraulic System Operation