Removal Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
- Disconnect the harness assembly from injection actuation pressure sensor (1) .
Illustration 1 | g01184033 |
- Remove injection actuation pressure sensor (1) .
- Inspect the condition of the O-ring seal on injection actuation pressure sensor (1). Replace the O-ring seal, if necessary.
Installation Procedure
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
- Install injection actuation pressure sensor (1). Tighten injection actuation pressure sensor (1) to a torque of 20 ± 2 N·m (15 ± 1 lb ft).
Illustration 2 | g01184033 |
- Connect the harness assembly to injection actuation pressure sensor (1) .