G3520B Industrial Engine Caterpillar


Oxygen Sensor - Calibrate

Usage:

G3520B GET
System Operation Description:

Periodic calibration of the oxygen sensor is required in order to ensure accurate readings and optimum engine performance. Refer to the Operation And Maintenance Manual for the maintenance interval schedule. The engine must be stopped and the sensor must be removed. The sensor must be placed in uncontaminated air in order to calibrate the sensor. The air must be free of exhaust.

During the calibration, the Electronic Control Module (ECM) first establishes the reference for zero percent of oxygen by reading the sensor after the sensor has cooled for two minutes. The ECM energizes the heater in the sensor for five minutes. Last, the ECM reads the percent of oxygen in the surrounding air. The surrounding air is assumed to be clean with approximately 20.95 percent oxygen. The calibration offset and the calibration range are determined from these two points.

Test Step 1. Check the Atmospheric Conditions

  1. Determine the ambient temperature, relative humidity, and barometric pressure.

  1. Use Table 1 to determine whether your relative humidity is within the permissible range for calibration of the oxygen sensor.

    1. Find the row for your ambient temperature.

      If the temperature is less than 12 °C (54 °F), use the 12 °C (54 °F) row.

      If the temperature is more than 38 °C (100 °F), do not calibrate the sensor.

    1. Find the column for your barometric pressure.

    1. Find the relative humidity in the cell that intersects your column and your row.

      If your relative humidity is equal to the humidity or greater than the humidity that is listed in the Table, do not calibrate the sensor.

      If the humidity is 90 percent or more, do not calibrate the sensor.

Table 1
Ambient Temperature, Barometric Pressure, and Relative Humidity for Calibration of the Oxygen Sensor    
Ambient Temperature     Barometric Pressure    

96 kPa (13.9 psi)

97 kPa (14.7 psi)    

99 kPa (14.4 psi)    

101 kPa (14.6 psi)    

102 kPa (14.8 psi)    

104 kPa (15 psi)    

105 kPa (15.2 psi)    

107 kPa (15.5 psi)    

109 kPa (15.8 psi)    

110 kPa (16 psi)    

112 kPa (16.2 psi)    

113 kPa (16.4 psi)    
Relative Humidity

12 °C (54 °F)    
90     90     90     90     90     90     90     90     90     90     90     90    

14 °C (57 °F)    
85     85     85     85     90     90     90     90     90     90     90     90    

16 °C (61 °F)    
75     75     75     75     80     80     80     80     85     85     85     85    

18 °C (64 °F)    
65     65     65     70     70     70     70     75     75     75     75     75    

20 °C (68 °F)    
60     60     60     60     60     65     65     65     65     65     65     70    

22 °C (72 °F)    
50     50     55     55     55     55     55     60     60     60     60     60    

24 °C (75 °F)    
45     45     45     50     50     50     50     50     50     55     55     55    

26 °C (79 °F)    
40     40     40     45     45     45     45     45     45     45     50     50    

28 °C (82 °F)    
35     35     40     40     40     40     40     40     40     40     45     45    

30 °C (86 °F)    
35     35     35     35     35     35     35     35     35     40     40     40    

32 °C (90 °F)    
30     30     30     30     30     30     35     35     35     35     35     35    

34 °C (93 °F)    
25     25     30     30     30     30     30     30     30     30     30     30    

36 °C (97 °F)    
25     25     25     25     25     25     25     25     25     30     30     30    

38 °C (100 °F)    
20     25     25     25     25     25     25     25     25     25     25     25    

Expected Result:

The temperature is less than 38 °C (100 °F). The ambient relative humidity is within the permissible range for calibration of the oxygen sensor.

Results:

  • OK - The ambient conditions are acceptable. Proceed to Test Step 2.

  • Not OK - The humidity is not acceptable.

    Repair: Do not calibrate the sensor until the humidity is acceptable.

    Stop.

Test Step 2. Check for Diagnostic Codes

  1. Restore the electrical power to the engine. Set the engine control to the STOP mode.

  1. Access the "Logged Diagnostic Codes" screen on the Caterpillar Electronic Technician ET. If the following codes are logged, clear the codes:

    • 1086-09 Oxygen Sensor Element not communicating on link

    • 1086-13 Oxygen Sensor Element calibration required

    • 1087-03 Oxygen Buffer Module short to +batt

    • 1087-08 Oxygen Buffer Module noisy signal

    • 1088-05 Oxygen Sensor Power Supply open circuit

    • 1088-06 Oxygen Sensor Power Supply short to ground

  1. Access the "Diagnostic Override" screen of Cat ET. Select "Diagnostics/Diagnostic Tests/Override Parameters".

  1. Turn ON the "Oxygen Sensor Override".

  1. Allow a minimum of 90 seconds for any diagnostic codes to be generated.

  1. Access the "Logged Diagnostic Codes" screen again. Look for the following diagnostic codes again: 1086-09, 1086-13, 1087-03, 1087-08, 1088-05 and 1088-06.

Expected Result:

None of the above diagnostic codes are logged.

Results:

  • No Codes - The circuit for the oxygen sensor is OK. Proceed to test Step 3.

  • Logged 1086-09, 1087-03 or 1087-08 - A 1086-09 1087-03 or 1087-08 diagnostic code is active.

    Repair: Refer to Troubleshooting, "Oxygen Sensor Signal".

    Stop.

  • Logged 1088-05 or 1088-06 Diagnostic Code - There is a problem with the supply voltage for the oxygen buffer.

    Repair: Refer to Troubleshooting, "Oxygen Sensor Buffer Supply".

    Stop.

Test Step 3. Calibrate the Oxygen Sensor

  1. Set the engine control to the OFF/RESET mode. Remove the electrical power from the engine.

    ------ WARNING! ------

    During operation, the oxygen sensor may reach temperatures that exceed 700 °C (1292 °F). Severe personal injury and property damage will result from contact with a hot oxygen sensor.

    Do not touch the sensor during engine operation, calibration, or testing. Allow the sensor to cool before moving the sensor. Wear gloves that resist heat. Do not place the sensor on or near any flammable material or any surface that can be damaged by high temperatures.

    ----------------------

  1. Disconnect the oxygen sensor from the oxygen buffer.

  1. Allow the sensor to cool sufficiently for removal. Then remove the sensor from the exhaust system.

  1. Connect the oxygen sensor to the oxygen buffer. Suspend the sensor in uncontaminated air.

  1. Restore the electrical power to the engine. Set the engine control to the STOP mode.

  1. Access the "Service/Calibrations/Oxygen Sensor" screen of Cat ET. Use Cat ET to start the calibration.

    Approximately 12 minutes are required for the calibration.

Expected Result:

Successful calibration is indicated by Cat ET.

Results:

  • OK - The calibration was successful. Proceed to Test Step 4.

  • Not OK - The calibration was not successful. Cat ET will display a diagnostic code.

    Repair: Troubleshoot the diagnostic code. Check the connectors for the oxygen sensor and the oxygen buffer. Repeat the calibration procedure. If the procedure is not successful after three attempts, obtain a new oxygen sensor and repeat the calibration procedure.

    Stop.

Test Step 4. Verify the Calibration of the Sensor

  1. Access the "Diagnostic Override" screen of Cat ET. Select "Diagnostics/Diagnostic Tests/Override Parameters".

  1. Turn ON the "Oxygen Sensor Override" parameter.

Expected Result:

The "Actual Oxygen" reading stabilizes to approximately 20.95 percent in about 30 seconds.

Results:

  • OK - The calibration of the oxygen sensor is verified. Allow the sensor to cool before you install the sensor. Stop.

  • Not OK - The calibration of the oxygen sensor is not verified.

    Repair: Repeat the calibration procedure.

    Stop.

Caterpillar Information System:

G3520B Industrial Engine Engine Speed/Timing Sensor - Calibrate
C27 and C32 Industrial and Petroleum Engines Intermittent Low Power or Power Cutout
2004/07/01 Some Older Mechanical Unit Injectors are Being Cancelled {1290}
3126E Truck Engines Maintenance Interval Schedule - Engines with a Deep Oil Sump
3126E Truck Engines Maintenance Interval Schedule - Engines with a Shallow Oil Sump
2004/10/01 Reduced Oil Change Intervals {7542}
2004/08/01 Special Instructions Are No Longer Announced In the Engine News {1000}
2004/08/01 Special Instructions Are No Longer Announced In the Truck Engine News {1000}
G3520B Industrial Engine Integrated Temperature Sensing Module (ITSM)
3412E, C30 and C32 Marine Engines Water Pump - Install
2004/07/01 A New Housing for the Speed/Timing Sensor and a New Speed/Timing Sensor are Used {1210, 1907}
EMCP3 ECM Connections
3500B High Displacement Air Inlet and Exhaust Lines
G3520B Industrial Engine Oxygen Sensor Buffer Supply
G3520B Industrial Engine Oxygen Sensor Signal
C15 and C18 Industrial Engines Engine Oil Pan - Remove and Install
G3500B Engines Engine Oil Lines
G3406 Engines Cylinder Head Valves
TH31-C9I, TH31-C9P, TH31-C9T, TH35-C13I, TH35-C13T, TH35-C15I and TH35-C15T Petroleum Power Train Packages and TH31-E61 and TH35-E81 Petroleum Transmissions Transmission Oil Filter (Transmission)
3126E Truck Engines Reference Material
C4.4 (Mech) Industrial Engine Battery - Replace
C4.4 (Mech) Industrial Engine Battery or Battery Cable - Disconnect
C7 Marine Engines Fuel Cooler - Remove and Install
C7 Marine Engines Engine Sensors - Remove and Install
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.