G3516B Engines Caterpillar


MID 036 - CID 1758 - FMI 03 Specific Humidity Sensor open/short to +batt

Usage:

G3516B 7EZ
Conditions Which Generate This Code:

The duty cycle of the pressure sensor for the specific humidity of the inlet air is greater than the maximum limit.

Additionally, neither of the following diagnostic codes are active:

  • 262 - 03 5 Volt DC Supply short to +batt

  • 262 - 04 5 Volt DC Supply short to ground

System Response:

The alarm output is activated. The code is logged.

Possible Performance Effect:

The engine performance is not affected.

Troubleshooting:

The condition indicates a possible open circuit or a short circuit.

Test Step 1. Perform the following diagnostic procedure: "PWM Sensor"

Results:

  • OK - STOP

Caterpillar Information System: