Cranking Dropouts (providing supply was at least 10 V before dropout and providing supply recovers to 5 V) ... 0 V for 50 ms
Maximum Operating Current (12 V) ... 290 mA
Maximum Operating Current (24 V) ... 210 mA
Maximum Standby Current (12 V) ... 50 mA
Maximum Standby Current (24 V) ... 30 mA
Alternator Input Range ... 15 VAC RMS to 300 VAC RMS
Alternator Input Frequency (at rated engine speed) ... 50 Hz or 60 Hz
Engine Speed Input Range (Clamped by transient voltage transient suppressors) ... 0.5 V to ± 70 V
Engine Speed Input Frequency (at rated engine speed) ... 10 Hz to 10,000 Hz
Start Relay Output (at supply voltage) ... 16 Amp DC
Fuel Relay Output (at supply voltage) ... 16 Amp DC
Programmable Relay Outputs (at supply voltage) ... 5 Amp DC
Length ... 144 mm ( 5.67 in)
Height ... 72 mm ( 2.83 in)
Width ... 118 mm ( 4.67 in)
Note: The dimensions exclude the key switch or the knob.
Charge Fail/Excitation Range ... 0 V to 35 V
Operating Temperature Range ... -30 °C to 55 °C (-22 °F to 131 °F)