Electronic Modular Control Panel II (EMCP II) Caterpillar


Fault Identification

Usage:

3406B 4JK

Table 1
Fault Code Description    
Indicator
left side of GSC    
Fault Code on upper display     DIAG Indicator     Fault Type     Topic    
Fault Alarm     CID FMI (1)     Flashing     Active Alarm     Troubleshooting Diagnostic Codes    
SP1, SP2, SP3, (1) Missing     Active Alarm     Diagnostic Code Procedure, "SP Fault Code"    
AL1 through AL4 (1) Missing     Active Alarm     Diagnostic System Procedures, "AL Fault Code"    
Fault Shutdown     CID FMI     Flashing     Active Shutdown     Troubleshooting Diagnostic Codes    
SP1, SP2, SP3, Missing     Active Shutdown     Diagnostic System Procedures, "SP Fault Code"    
Dedicated Shutdown:        
Flashing     Missing     Missing     Active Alarm     Troubleshooting Dedicated Shutdown Indicators    
On Continuously     Missing     Missing     Active Shutdown    
None     CID FMI (2)     On Continuously     Inactive Alarm     Troubleshooting Diagnostic Codes    
CID FMI (2) On Continuously     Inactive Shutdown     Troubleshooting Diagnostic Codes    
SP1, SP2, SP3, Missing     Inactive Shutdown     Diagnostic System Procedures, "SP Fault Code"    
Missing Missing     Undiagnosed Shutdown     Symptom Procedures    
( 1 ) Fault code is shown after the alarm code key is pressed.
( 2 ) Fault Code is stored in the fault log of the GSC. To view the fault code, see Systems Operation, "Fault Log Viewing OP1" within the topic Service Mode.



Illustration 1g00614724

GSC Display Area

(1) Dedicated shutdown indicators

(2) Spare fault indicators

(3) Fault shutdown indicator

(4) Fault alarm indicator

(5) Upper display

(6) Lower display

(7) Keypad

(8) DIAG indicator

Faults that are detected and diagnosed by the GSC are shown to service personnel in the display area of the GSC. The GSC uses dedicated shutdown indicators (1), fault shutdown indicator (3), fault alarm indicator (4), "DIAG" indicator (8), upper display (5) and lower display (6) to tell service personnel about a fault. Perform the following procedure in order to identify the fault that is detected by the GSC.

Note: The "DIAG" indicator (8) functions when diagnostic information is available from the GSC.

  1. Make a note of the indicators that are functioning on the left side of the "GSC".

  1. View the fault code on the upper display (5). If the fault alarm indicator (4) is FLASHING and no fault code is present on the upper display (5), press the alarm codes key in order to view the fault code.

  1. Make a note of whether or not "DIAG" indicator (8) is FLASHING ON CONTINUOUSLY or MISSING.

  1. On the fault identification chart, look at the first column. Locate the fault indicator that is functioning.

  1. Go to the second column in the chart. Find the fault code that is presently shown on the upper display (5) .

  1. Go to the third column in the chart which describes the status of "DIAG" indicator (8) .

  1. Read the last two columns in order to find the type of fault and corresponding topic within this module.

Caterpillar Information System:

Electronic Modular Control Panel II (EMCP II) General Information
3024C Engine for Caterpillar Built Machines Rocker Shaft - Assemble
3024C Engine for Caterpillar Built Machines Rocker Shaft - Disassemble
Machine Security System Product Identification Number - Program
3024C Engine for Caterpillar Built Machines Rocker Shaft and Pushrod - Remove
Machine Security System Time - Set
2001/10/01 Commercial Folded Core Radiators Can Be Converted to Multiple Row Module Radiators {1353}
2001/10/01 Improved Troubleshooting Procedures for EMCPII, EMCPII+, and EMCPII+P Annunciators {4490}
Automatic Transfer Switches CTG, CTGD Series Timers
3054 and 3056 Industrial and Generator Set Engines Fuel Injection Nozzles
3054 and 3056 Marine Generator Set Engines Fuel Injection Pump
2001/11/01 A New Rear Housing Assembly is Available {1157}
Electronic Modular Control Panel II (EMCP II) Service Tools
3054 and 3056 Engines 520 Generator Set Control Panel General Information
3054 and 3056 Industrial and Generator Set Engines Cylinder Head Valves
3054 and 3056 Industrial and Generator Set Engines Cylinder Head
Electronic Modular Control Panel II (EMCP II) Troubleshooting Diagnostic Codes
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0334 - FMI 04 (for MUI and PEEC Engines)
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0336 - FMI 02
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0441 - FMI 12 (for EUI Engines)
C0.5, C0.7, C1.1/3011C, C1.5/3013C, C1.6 and C2.2/3024C/3024CT Industrial Engines and Engines for Caterpillar Built Machines Flywheel - Remove
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0441 - FMI 12 (for PEEC Engines)
C1.1, C1.5 and C2.2 Engines for Caterpillar Built Machines Flywheel - Install
Electronic Modular Control Panel II+ (EMCP II+) GSC CID 0442 - FMI 12
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.