3512B Marine Auxiliary Engine Caterpillar


MID 047 - CID 0248 - FMI 09 CAT Data Link not communicating

Usage:

3512B AAG
Conditions Which Generate This Code:

The battery voltage to the Electronic Control Module (ECM) has been above 9 VDC for the last two seconds. The engine is not cranking. Communications with the VIMS and/or the VIDS has not been established for six seconds. Communication was lost for two or more seconds. The CID-FMI is logged in memory.

System Response:

The CID-FMI may be viewed on a display module or the Caterpillar Electronic Technician (ET). The features which receive inputs from the CAT Data Link are disabled.

Test Step 1. Perform the following test: CAT Data Link

Results:

  • OK - Stop.

  • REPAIRED, OK - Stop.