3412E Engine for Caterpillar Built Machines Caterpillar


Sensor Signal (Analog, Active) - Test

Usage:

24H 7KK
System Operation Description:

Use this procedure to troubleshoot the electrical system if a problem is suspected with the sensors or if any one of the diagnostic codes in Table 1 is active or easily repeated.

Table 1
Diagnostic Codes Table    
Code and Description     Conditions which Generate this Code     System Response    
94-3 Fuel Delivery Pressure Sensor voltage above normal     The Electronic Control Module (ECM) detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
500 kPa (75 psi).    
94-4 Fuel Delivery Pressure Sensor voltage below normal     The Electronic Control Module (ECM) detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
500 kPa (75 psi).    
100-3 Engine Oil Pressure Sensor voltage above normal     The Electronic Control Module (ECM) detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
500 kPa (75 psi).    
100-4 Engine Oil Pressure Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
110-3 Engine Coolant Temperature Sensor voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
−40 °C (−40 °F).    
110-4 Engine Coolant Temperature Sensor voltage below normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
−40 °C (−40 °F).    
164-0 Injector Actuation Pressure high - most severe (3)     The ECM detects injection actuation pressure that is above
24 MPa (3481 psi) for one second.
The ECM has been powered for three seconds.    
The code is logged.
The fuel limit is set to a predetermined value.    
164-3 Injector Actuation Pressure voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
12 MPa (1741 psi).
The current to the IAPCV is set to 0.23 Amp.
The fuel limit is set to a predetermined value.    
164-4 Injector Actuation Pressure voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.
This diagnostic code indicates the ECM may be faulty    
The code is logged.
The value of the parameter is set to a pressure of
12 MPa (1741 psi).    
174-3 Fuel Temperature Sensor voltage above normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
30 °C (86 °F).    
174-4 Fuel Temperature Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
30 °C (86 °F).    
175-3 Engine Oil Temperature Sensor voltage above normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
90 °C (194 °F).    
175-4 Engine Oil Temperature Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
90 °C (194 °F).    
273-0 Turbocharger Outlet Pressure Sensor high - most severe (3)     The ECM detects turbocharger outlet pressure is above normal for five seconds.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
0.0 kPa (0.0 psi).    
273-3 Turbocharger Outlet Pressure Sensor voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
0.0 kPa (0.0 psi).    
273-4 Turbocharger Outlet Pressure Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
0.0 kPa (0.0 psi).    
274-3 Atmospheric Pressure Sensor voltage above normal     The ECM detects signal voltage that is above normal for one second.
The ECM has been powered for three seconds.    
The code is logged.
The value of the parameter is set to a pressure of
45 kPa (7 psi).    
274-4 Atmospheric Pressure Sensor voltage below normal     The ECM detects signal voltage that is below normal for one second.
The ECM has been powered for three seconds.    

System Operation

Use this procedure to troubleshoot any suspect problems with the following pressure sensors:

  • Engine oil pressure sensor

  • Atmospheric pressure sensor

  • Turbocharger outlet pressure sensor

  • Injection actuation pressure sensor

The ECM performs an automatic calibration of these sensors whenever the ECM is powered and the engine is off for at least five seconds. During an automatic calibration, the ECM calibrates pressure sensors to the value of the atmospheric pressure sensor and against an acceptable offset pressure range.

Use this procedure to troubleshoot any suspect problems with the following temperature sensors:

  • Engine oil temperature sensor

  • Fuel temperature sensor

  • Coolant temperature sensor

The supply voltage is routed to terminal A of each sensor connector. The sensor return is routed to terminal B of each sensor connector. The sensor signal is routed to terminal C of each sensor connector. The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.

The ECM continuously outputs a pull-up voltage on the input terminal from an analog sensor. The ECM uses this pull-up voltage in order to detect an open or a short in the signal circuit. When the ECM detects the presence of a voltage that is above the normal range of the sensor on the signal circuit, the ECM will generate an open circuit diagnostic code 3 for that sensor. When the ECM detects the absence of the pull-up voltage on the signal circuit, the ECM will generate a short circuit diagnostic code 4 for that sensor. The presence of pull-up voltage at the sensor connector indicates that the wires from the sensor connector to the ECM are not open or shorted to ground.




Illustration 1g01394867

Typical schematic




Illustration 2g01408229

Component location

(1) Coolant temperature sensor

(2) Turbocharger outlet pressure sensor

(3) Injection actuation pressure sensor

(4) Fuel temperature sensor

(5) Atmospheric pressure sensor

(6) Engine oil pressure sensor

(7) Engine oil temperature sensor

Test Step 1. Inspect the Electrical Connectors and Wiring

  1. Remove electrical power from the ECM.



    Illustration 3g01408242

    ECM

    (8) J1/P1 connectors

    (9) J2/P2 connectors

  1. Thoroughly inspect the J1/P1 and thoroughly inspect the J2/P2 ECM connectors. Thoroughly inspect any connectors that are associated with the analog sensors. Refer to Troubleshooting, "Electrical Connectors - Inspect".



      Illustration 4g01394996

      P1 ECM connector

      (P1-36) Sensor supply

      (P1-30) Sensor return

      (P1-37) Injection actuation pressure sensor

      (P1-31) Engine oil temperature sensor




      Illustration 5g01395003

      P2 ECM connector

      (P2-23) Turbocharger outlet pressure sensor

      (P2-8) Engine oil pressure sensor

      (P2-20) Atmospheric pressure sensor

      (P2-9) Engine coolant temperature sensor

      (P2-15) Fuel temperature sensor




      Illustration 6g01159881

      Sensor connector

      (A) 5 V sensor supply

      (B) Sensor return

      (C) Signal

    1. Check the torque of the allen head screws for the ECM connectors.

    1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit for the analog sensors.

    1. Check the harness and wiring for abrasion and for pinch points from the analog sensors to the ECM.

Expected Result:

All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points. All connections and grounds are tight and free of corrosion.

Results:

  • OK - The connectors and wiring appear to be OK. Proceed to Test Step 2.

  • Not OK - The connectors and/or wiring are not OK.

    Repair: Perform the necessary repairs and/or replace parts, if necessary. Refer to Troubleshooting, "Electrical Connectors - Inspect".

    STOP

Test Step 2. Check for "Active" or for "Logged" Diagnostic Codes

  1. Connect Caterpillar Electronic Technician (ET) to the service tool connector.

  1. Restore electrical power to the ECM.

  1. Monitor the diagnostic codes on Cat ET. Check and record any diagnostic codes.

    Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

  1. Determine if a diagnostic code has occurred several times.

    Note: A diagnostic code that is logged several times is an indication of an intermittent problem. Most intermittent problems are the result of a bad connection between a socket and a pin in a connector or a bad connection between a wire and a terminal. The problem may be caused by moisture, corrosion, or wear.

  1. Determine if the problem is active and related to one of the following diagnostic codes:

    • -3

    • -4

Expected Result:

A diagnostic code is not active.

Results:

  • OK - A diagnostic code is not active.

    Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".

    STOP

  • Not OK - A -3 code or a -4 code is active. Proceed to Test Step 3.

Test Step 3. Check the 5 Volt Supply Voltage at the Sensor Connector

  1. Do not disconnect the connector for the suspect sensors(s).

  1. Connect a voltmeter between pin A and pin B on the sensor side of the connector for the suspect sensor.

  1. Measure the voltage between pin A and pin B for the suspect sensor(s).

  1. Wiggle the harness while you monitor the voltage on the voltmeter. Perform the 45 N (10 lb) pull test on each wire in the circuit. Each terminal and each connector should easily withstand 45 N (10 lb) of tension and each wire should remain in the connector body. This test checks whether the wire was properly crimped in the terminal and whether the terminal was properly inserted into the connector.

Expected Result:

The supply voltage is approximately 5.0 ± 0.5 VDC.

Results:

  • OK - The supply voltage is approximately 5.0 ± 0.5 VDC. An active -3 diagnostic code is present. Proceed to Test Step 4.

  • OK - The supply voltage is approximately 5.0 ± 0.5 VDC. An active -4 diagnostic code is present. Proceed to Test Step 6.

  • Not OK - The supply voltage is not approximately 5.0 ± 0.5 VDC.

    Repair: There is an open in the wiring or connectors between the suspect sensor(s) and the ECM. Inspect the wiring and connectors.

    STOP

Test Step 4. Check for Voltage on the Signal Wire

  1. Measure the voltage on the harness side of the sensor connector between pin B and pin C for the suspect sensor(s).

Expected Result:

The signal voltage is less than battery voltage.

Results:

  • OK - The signal voltage is less than battery voltage. Proceed to Test Step 5.

  • Not OK - The signal voltage is equal to battery voltage.

    Repair: There is a short in the harness to the Battery. Repair the wiring.

    STOP

Test Step 5. Create a Short at the Sensor Connector

  1. Remove electrical power from the ECM.

  1. Disconnect the suspect sensor(s).

  1. Use a wire jumper in order to create a short between terminal C (signal) and terminal B (sensor return) at the connector for the suspect sensor(s).

  1. Restore electrical power to the ECM.

  1. Monitor the diagnostic codes on Cat ET. Check for an active -4 diagnostic code for the suspect sensor.

    Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

  1. Remove electrical power from the ECM.

Expected Result:

A -4 diagnostic code is now active for the suspect sensor(s).

Results:

  • OK - A -3 diagnostic code was active before creating the short at the sensor connector. A -4 diagnostic code became active after creating the short at the sensor connector. The harness and the ECM are OK. There may be a problem with the sensor.

    Repair: Temporarily connect a new sensor to the harness, but do not install the new sensor in the engine. Verify that there are no active diagnostic codes for the sensor. If there are no active diagnostic codes for the sensor, permanently install the new sensor. Clear any logged diagnostic codes.

    STOP

  • Not OK - A -3 diagnostic code is still active for the suspect sensor(s). The problem may be in the harness or with the ECM. Proceed to Test Step 7.

Test Step 6. Create an Open at the Suspect Sensor Connector

  1. Remove electrical power from the ECM.

  1. Disconnect the sensor connector of the suspect sensor(s) with the active 4 diagnostic code.

  1. Restore electrical power to the ECM.

  1. Monitor the diagnostic codes on Cat ET. Check for an active -3 diagnostic code for the suspect sensor(s).

    Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

  1. Remove electrical power from the ECM.

Expected Result:

A -3 diagnostic code is now active for the suspect sensor(s).

Results:

  • OK - A -4 diagnostic code was active before disconnecting the sensor(s). A -3 diagnostic code became active after disconnecting the sensor(s). The harness and the ECM are OK. There may be a problem with the sensor(s).

    Repair: Temporarily connect a new sensor(s) to the harness, but do not install the new sensor(s) in the engine. Verify that there are no active diagnostic codes for the sensor(s). If there are no active diagnostic codes for the sensor(s), permanently install the new sensor(s). Clear any logged diagnostic codes.

    STOP

  • Not OK - A -4 diagnostic code is still active for the suspect sensor(s). Leave the sensor(s) disconnected. The problem may be in the harness or with the ECM. Proceed to Test Step 7.

Test Step 7. Test the Operation of the ECM

  1. Fabricate jumper wires that can be used to replace the signal wire in the ECM connector for the suspect sensor(s). Crimp a connector socket to one end of the jumper wire.

  1. Disconnect the appropriate ECM connector for the suspect sensor(s).

  1. Remove the signal wire for the suspect sensor(s) from the ECM connector.

  1. Install the jumper wire into the terminal location for the suspect sensor(s) at the ECM connector.

  1. Connect the ECM connector.

  1. Check the operation of the ECM by creating an open at the ECM:

    1. Hold the loose end of the jumper wire away from any components in order to create an open circuit condition.

    1. Restore electrical power to the ECM.

    1. Monitor the active diagnostic code screen on Cat ET. Check for a -3 diagnostic code for the suspect sensor(s).

      Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

  1. Check the operation of the ECM by creating a short circuit at the ECM:

    1. Short the jumper wire for the suspect sensor(s) to the analog return in order to create a short circuit condition.

    1. Monitor the active diagnostic code screen on Cat ET. Check for a -4 diagnostic code for the suspect sensor(s).

      Note: Wait at least 30 seconds in order for the diagnostic codes to become active.

  1. Remove electrical power from the ECM.

  1. Remove all jumper wires. Return the wiring to the original configuration.

Expected Result:

A -3 diagnostic code is active when the sensor(s) signal wire is removed from the ECM connector. A -4 diagnostic code is active when the signal wire is shorted to the return.

Results:

  • OK - The ECM is operating properly. The problem is in the wiring between the ECM and the connector for the sensor(s).

    Repair: If the code is active for more than one sensor, the problem is most likely in the return wire for the sensor(s). Repair the analog return wire for the sensor(s) or replace the harness.If the code is only active for one sensor, the problem is most likely in the signal wire for the sensor. Repair the signal wire for the sensor.

    STOP

  • Not OK - One of the following conditions exists: The -3 diagnostic code is not active when a signal wire is disconnected. The -4 diagnostic code is not active when the wire jumper is shorted to the analog return.

    Repair: Replace the ECM. Refer to Troubleshooting, "ECM - Replace". Verify that the problem is resolved.

    STOP

Caterpillar Information System:

2007/07/16 An Improvement has been Made to the Bulk Material for Hose Assemblies {5057}
308D CR Mini Hydraulic Excavator Caterpillar Approved Work Tools
C6.6 Engines for Caterpillar Built Machines Fuel Priming Pump - Remove and Install - Mechanical Priming Pump
323D Excavator Refrigerant Dryer - Replace
330D Forest Machine Machine Systems Final Drive and Travel Motor - Remove
M316D Wheeled Excavator C6.6 Engine Supplement Engine Rear Mount - Remove and Install
M316D Wheeled Excavator C6.6 Engine Supplement Engine Front Mount - Remove and Install - Right Side
New Replacement Options for Serviced Engines{1000} New Replacement Options for Serviced Engines{1000}
M316D Wheeled Excavator C6.6 Engine Supplement Engine Enclosure Group - Remove and Install
2007/07/23 A New Relay Eliminates Issues of Hard Starting {1426}
303.5 Mini Hydraulic Excavator Bucket Tips - Inspect/Replace - J200 Tips
325C Excavator Maintenance Interval Schedule
320D Forest Machines Power Receptacle - If Equipped
303C CR, 303.5C CR, 304C CR and 305C CR Mini Hydraulic Excavators Bucket Tips - Inspect/Replace - Vertical Retention System for a Round Hole Tip
320D Forest Machines Specifications
GSH9B, GSH15B and GSH20B Orange Peel Grapples Grapple Link
320D Forest Machines Fuses - Replace
GSH9B, GSH15B and GSH20B Orange Peel Grapples Grapple Link
GSH9B, GSH15B and GSH20B Orange Peel Grapples Grapple Link
3412E Engine for Caterpillar Built Machines Sensor Supply - Test
GSH9B, GSH15B and GSH20B Orange Peel Grapples Grapple Link
GSH9B, GSH15B and GSH20B Orange Peel Grapples Grapple Link
XQP150 Rental Generator Set Water Pump - Inspect
M315D, M315D Series 2, M315D2, M317D Series 2 and M317D2 Wheeled Excavators Machine Systems Stabilizer - Remove and Install - Rear
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.