330C Excavator Hydraulic System Caterpillar


Main Pump (Flow) - Test - Constant Horsepower Flow Control

Usage:

330C MSD
This test measures individual pump flow at the pump. Each pump is tested individually for output flow at specified pressures. The pump that is not being tested is not under load and the pump remains at low pressure standby.


Illustration 1g00817116

The electronic control module is located in the compartment behind the cab.

(1) Alarm lamp

(2) Electronic control module




Illustration 2g00671482

(3) Monitor

(4) Message display

Note: Before starting main pump flow tests, check message display (4) on monitor (3) and alarm lamp (1) on electronic control module (2) for normal operation. Lamp (1) should be green. If no faults are present, perform the operational checks. Refer to Testing and Adjusting, "Operational Checks".

Note: If the operational checks indicate that slow speed of an implement is common to the circuits of one pump, the problem is most likely in the hydraulic system. Then perform the pump flow tests. Refer to Testing and Adjusting, "Piston Pump (Main) - Test".

Note: If the operational checks indicate that slow speed of an implement is common to both pump circuits, the problem may be in the engine, the fuel, or the working altitude.




Illustration 3g00671496

Flow meter tool layout

(1) Swing motor

(2) Connector at swing motor

(3) 6V-9840 Swivel tee

(4) Makeup line (swing motor)

(6) Negative flow control line (right pump)

(10) 4C-9910 Portable hydraulic tester (flow meter)

(11) Delivery line (left pump)

(12) Delivery line (right pump)

(13) Negative flow control line (left pump)

(17) 9U-7335 Blocking cover

(23) Right pump

(24) Left pump

(29) 1U-8303 Fitting

(30) 5K-9090 O-Ring seal

(31) 5P-0201 Hose

(32) 5P-1010 Sleeve

(33) 4C-8767 Coupling

(34) 7M-8485 O-Ring seal

(35) 4C-6481 Coupler assembly

(36) 4C-6482 Nipple assembly

(37) 4I-6141 Coupling

(38) 8C-9026 Adapter

(39) 6K-6307 O-Ring seal

(40) 6V-9854 Swivel elbow

(42) 1P-3703 Rectangular seal

(46) 8T-4184 Bolt

(47) 8T-4223 Hard washer

(48) 6V-0400 Half flange

(49) 1U-8292 Adapter




Illustration 4g00817191

Circuit diagram

(1) Swing motor

(2) Connector

(3) Tee

(4) Makeup line

(5) Main control valve

(8) Pressure tap (left pump delivery pressure)

(9) 8T-0861 Pressure gauge

(10) 4C-9910 Portable hydraulic tester (flow meter)

(11) Delivery line for left pump

(12) Delivery line from right pump

(16) Pressure tap (right pump delivery pressure)

(17) 9U-7335 Blocking cover

(20) 8T-0856 Pressure gauge

(21) Engine

(22) Multitach

(23) Right pump

(24) Left pump

(40) Elbow

(50) Pressure tap (power shift pressure)

Right Pump


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.

Dispose of all fluids according to local regulations and mandates.


Note: Perform the test for the right pump and the test for the left pump one at a time.




Illustration 5g00817197

Pump compartment

(8) Pressure tap (left pump delivery pressure)

(12) Delivery line for right pump

(16) Pressure tap (right pump delivery pressure)

(23) Right pump

(24) Left pump

(50) Pressure tap (power shift pressure)

  1. Position the machine on level ground.

  1. Stop the engine.

  1. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System Pressure - Release".

  1. Install the following tools in accordance with the flow meter tool layout and the circuit diagram. Refer to Illustration 3 and Illustration 4.

    1. Disconnect delivery line (12) from right pump (23) .

    1. Install seal (42), half flanges (48) and blocking cover (17) to the end of delivery line (12) by using bolts (46) and washers (47) .

    1. Assemble and install seal (42), adapter (49), seals (34), fitting (29) and nipple assembly (36) on right pump (23) by using half flanges (48), bolts (46) and washers (47) .



      Illustration 6g00669270

      Swing motor (top view)

      (1) Swing motor

      (2) Connector

      (3) Tee

      (4) Makeup line

      (40) Elbow

    1. Disconnect makeup line (4) from connector (2) at swing motor (1) .

    1. Assemble and install seals (30), tee (3), swivel elbow (40) and coupling (37) to connector (2) at swing motor (1) .

    1. Install seal (30) and makeup line (4) to tee (3) .

    1. Connect portable hydraulic tester (10) and the test hoses between nipple assembly (36) at right pump (23) and coupling (37) at the swing motor.

    1. Connect 4900 kPa (700 psi) pressure gauge (20) to tap (50) for power shift pressure. Connect 49000 kPa (7100 psi) pressure gauge (9) to tap (16) for right pump delivery pressure.

    1. Install multitach group (22) on engine (21). This is used to monitor engine speed.

Left Pump


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.

Dispose of all fluids according to local regulations and mandates.


Note: Perform the test for the right pump and the test for the left pump one at a time.




Illustration 7g00817210

Pump compartment

(8) Pressure tap (left pump delivery pressure)

(11) Delivery line for left pump

(16) Pressure tap (right pump delivery pressure)

(23) Right pump

(24) Left pump

(50) Pressure tap (power shift pressure)

  1. Position the machine on level ground.

  1. Stop the engine.

  1. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System Pressure - Release".

  1. Install the following tools in accordance with the flow meter tool layout and the circuit diagram. Refer to Illustration 3 and Illustration 4.

    1. Disconnect delivery line (11) from left pump (24) .

    1. Install seal (42), half flanges (48) and blocking cover (17) to the end of delivery line (11) by using bolts (46) and washers (47) .

    1. Assemble and install seal (42), adapter (49), seals (34), fitting (29) and nipple assembly (36) on left pump (24) by using half flanges (48), bolts (46) and washers (47) .



      Illustration 8g00669270

      Swing motor (top view)

      (1) Swing motor

      (2) Connector

      (3) Tee

      (4) Makeup line

      (40) Elbow

    1. Disconnect makeup line (4) from connector (2) at swing motor (1) .

    1. Assemble and install seals (30), tee (3), swivel elbow (40) and coupling (37) to connector (2) at swing motor (1) .

    1. Install seal (30) and makeup line (4) to tee (3) .

    1. Connect portable hydraulic tester (10) and the test hoses between nipple assembly (36) at right pump (23) and coupling (37) at the swing motor.

    1. Connect 4900 kPa (700 psi) pressure gauge (20) to pressure tap (50) for power shift pressure. Connect 49000 kPa (7100 psi) pressure gauge (9) to pressure tap (8) for left pump delivery pressure.

    1. Install multitach group (22) on engine (21). This is used to monitor engine speed.

Test

Note: Perform the test for the front pump and the test for the rear pump one at a time.

------ WARNING! ------

To prevent personal injury or equipment damage from failure of the hydraulic test equipment or associated circuit components because of blocked pump flow, make sure that the test equipment valves are fully open before starting the engine.

----------------------

------ WARNING! ------

To prevent personal injury and/or equipment damage from failed lines or components while the hydraulic test equipment is returned to the open flow position, slowly open the hydraulic test equipment valve while monitoring the pump flow.

If pump flow does not increase as the valve is opened, shut the engine off and determine what is preventing the pump from upstroking.

----------------------

  1. Start the engine.

  1. Place the machine controls at the following settings: engine speed dial "10" and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test" for engine rpm settings.

  1. Increase the hydraulic oil temperature to 55° ± 5°C (131° ± 9°F).



    Illustration 9g00672009

    Monitor

    (A) Message display

    (B) Keypad

    (C) Up key

    (D) Left key

    (E) Down key

    (F) Right key

    (G) Cancel key

    (H) Set key

    (I) OK key

    (J) Menu key

  1. Start Service Mode and input a fixed power shift pressure of 2400 ± 50 kPa (350 ± 7 psi).

    1. Press menu key (J) .

      Note: If more than thirty seconds pass between pushing the keys on the keypad, the menu mode will be cancelled and the previous display will be restored to message display (A) .

    1. Press down key (E) in order to highlight the menu item "SERVICE OPTIONS" on the message display. Press OK key (I) .

    1. Input the password "FFF2". Press left key (D) or right key (F) in order to change the position of the flashing character. Press up key (C) or press down key (E) in order to change the value of the flashing character. Press OK key (I) after the correct password is displayed.

    1. Press down key (E) once in order to highlight the second line on the message display.

    1. Press right key (F) repeatedly until "DEVICE TEST" appears on the message display.

    1. Press down key (E) in order to move down one line on the message display.

    1. Press right key (F) until the "PS PRV - FIXED" appears on the message display.

    1. Press down key (E) .

    1. Press OK key (I). The display on line 4 of the message display will now change to a numeric value. These characters represent the power shift pressure (kPa).

    1. Press left key (D) or right key (F) in order to increase or decrease the numeric value that is displayed on line 4 of the message display. Pressing left key (D) one time decreases the power shift pressure 10 kPa (1.5 psi). Pressing right key (F) one time increases the power shift pressure 10 kPa (1.5 psi).

      Note: The value for power shift pressure on the monitor may not always match the pressure reading on the pressure gauge. Adjust the value on the monitor until the desired power shift pressure is attained on the pressure gauge that is connected to the pressure tap for power shift pressure. The actual power shift pressure must be 2400 ± 50 kPa (350 ± 7 psi) on the pressure gauge.

      Note: To prevent a change in power shift pressure during the pump flow test, do not turn the engine start switch to the OFF position.

      Note: Refer to Service Manual, "Engine and Pump Electronic Control System" for additional information on Service Mode.

  1. In order to perform flow measurements for either one of the pumps, the other pump must not be under load.



    Illustration 10g00670500

    Portable hydraulic tester (flow meter)

    (10) Portable hydraulic tester (flow meter)

    (22) Multitach

    (26) Valve

  1. Turn valve (26) on portable hydraulic tester (10) clockwise. Record pump flow at each of the following pressures in Table 1. Use pressure gauge (9) at pressure tap (16) to monitor right pump delivery pressure or use pressure tap (8) to monitor left pump delivery pressure.



Illustration 11g00817128

P-Q characteristic curve

Table 1
Pump Flow Test    
    Measuring Points    

13700 kPa (1975 psi)

17700 kPa (2550 psi)    

19600 kPa (2850 psi)    

25500 kPa (3700 psi)    

29400 kPa (4250 psi)    
Flow measured liter/min (US gpm)     Right Pump                        
Left Pump                    
Oil temperature °C (°F)                        
               
Engine speed (rpm)                        
               
Flow corrected liter/min (US gpm)     Right Pump                        
Left Pump                    
Specification for flow rate liter/min (US gpm)     New    
203 ± 10 (54 ± 2.6)    

181 ± 10 (48 ± 2.6)    

170 ± 10 (45 ± 2.6)    

140 ± 10 (37 ± 2.6)    

125 ± 10 (33 ± 2.6)    
Service limit
191 (50)    

142 (38)    

134 (35)    

99 (26)    

88 (23)    

Note: Specifications for output flow rates are based on an engine speed of 1800 rpm. To attain more accurate test results, measured flow should be corrected with the following calculation.

Table 2
Corrected flow     =     Measured flow x 1800 rpm    
measured rpm

Note: Specifications for output flow rates are based on a power shift pressure at the pump of 2400 ± 50 kPa (350 ± 7 psi). The output flow rate changes approximately 7 L/min (1.8 US gpm) for each 100 kPa (14 psi) of power shift pressure in the lower range of the constant horsepower control. The output flow rate changes approximately 3 L/min (0.8 US gpm) for each 100 kPa (14 psi) of power shift pressure in the higher range of the constant horsepower control.

Note: If the output flow rate of the pump is not within the specification, disconnect the negative flow control line from the pump that is being tested and perform the test again.

Note: Flow measurements must be done only during pressure rise.

Caterpillar Information System:

C7 Engine for AP-1000D, AP-1055D, BG-2455D, and BG-260D Asphalt Pavers CID 0269 FMI 03 Sensor Supply too high
C11 and C15 Engines for Caterpillar Built Machines CID 0269 FMI 04 Sensor Supply too low
330C Excavator Hydraulic System Fan Motor Speed (Hydraulic Oil Cooler) - Test and Adjust
330C Excavator Hydraulic System Fan Motor (Hydraulic Oil Cooler) - Test - Measurement of Case Drain Oil
330C Excavator Hydraulic System Fan Motor (Hydraulic Oil Cooler) - Test - Measurement of Case Drain Oil
302.5C Mini Hydraulic Excavator Machine System Specifications Bucket Cylinder
330C Excavator Hydraulic System Relief Valve (Crossover) - Test and Adjust
330C Excavator Hydraulic System Travel Motor - Test - Measurement of Case Drain Oil
330C Excavator Hydraulic System Swing Bearing Movement - Measure
325D and 329D Excavators Fuses - Replace
365C Front Shovel Hydraulic System Specifications
365C Front Shovel Hydraulic System Relief Valve (Line) - Test and Adjust
330C Excavator Hydraulic System Pump Control (Output Flow) - Adjust
330C Excavator Hydraulic System Pump Control (Negative Flow) - Test
C7 Engine for AP-1000D, AP-1055D, BG-2455D, and BG-260D Asphalt Pavers CID 1603 FMI 12 Machine Control Module malfunction
330C Excavator Hydraulic System Pump Control (Negative Flow) - Adjust
330C Excavator Hydraulic System Gear Pump (Pilot) - Test
330C Excavator Hydraulic System Gear Pump (Fan Motor) - Test
330C Excavator Hydraulic System Specifications
C27 and C32 Engines for Caterpillar Built Machines CID 1785 FMI 03 Intake Manifold Pressure Sensor voltage high
C27 and C32 Engines for Caterpillar Built Machines CID 1785 FMI 04 Intake Manifold Pressure Sensor voltage low
C27 and C32 Generator Set Engines CID 1785 FMI 10 Intake Manifold Pressure Signal abnormal rate of change
C7 Engine for AP-1000D, AP-1055D, BG-2455D, and BG-260D Asphalt Pavers CID 1603 FMI 09 Machine Control Module not communicating on link
C7 and C9 Engines for Caterpillar Built Machines E198 Low Fuel Pressure
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.