A new 458-6660 Machine Software Gp is now available for the machines listed above. The new machine software group updates the following changes in the machine Electronic Control Module (ECM).
- Corrects Un-commanded Motion Detection (UCMD) error on MTL/CTL resulting from 8V sensor network shorts to ground.
- Reduces false UCMD shutdown events during 2-Speed upshift.
- Restores functionality of the 30 second Anti-Theft Grace Period option.
- Added Raise Only Self Level to 242D, 257D and 259D machines.
- Added the ability to clear Anti-Theft PINs through ET after MSS is uninstalled.
- Minor Self Level retuning to some models.
- Corrected Auxiliary Rate Limit issue that would cause a bucket claw to drift closed briefly after command as halted.
- Improved UCMD at low Creep speed settings.
- Corrected drive solenoid current dither setting. This setting could result in poor start-to move, delayed or sluggish steering response, poor"straight-line" tracking at lower travel speeds or creep settings.
- Corrected COOL Mode (Parked Start-Up) elevated engine idle value.
- Corrected Glow Plug not functioning issue on Tier 4i/Tier two models.
- Corrected false codes E876 for High Voltage.
- Added COLD Mode (Parked Running) elevated engine idle feature.
- Contained minor Snubbing improvements.
- Corrected minor Creep speed display bug.
- Corrected Selectable Pattern feature installation bug.
- Corrected Software Enabled Attachment (SEA) retention during software update.
- Moved Speed Limit setting from operator profiles to the master profile only.
- Added minimum Speed Limit setting of 20 percent of maximum.
- Increased the speed of Creep ON/OFF commands.
- Increased number of Invalid Anti-Theft PIN attempts from three to five before lockout period employed.
- Increased Minimum Fan Speed Calibration range for certain models.
- Improved Self Level Calibration success rate.
- Improved 2-Speed Shift tuning.
Go to SIS Web to make sure that the new Flash File part number is still the latest Flash File part number. A newer Flash File part number may be available. SIS Web only displays the latest available flash file. The new software is available in the form of a flash file through Caterpillar Service Information System (SIS).