3400 ELECTRONIC MARINE ENGINES Caterpillar


Connecting the PORT and STBD Throttle Without Engine Synchronization

Usage:

Connecting the STBD Primary Throttle Position Sensor (TPS)


STBD Throttle

1. Connect PIN 5 of the P2 DT Connector to PIN A (+ Battery) of the TPS.

2. Connect PIN 6 of the P2 DT Connector to PIN B (- Battery) of the TPS.

3. Connect PIN 4 of the P2 DT connector to PIN C (throttle) of the TPS.

NOTE: PIN C is the throttle output of the STBD TPS and is a Pulse Width Modulated Signal (PWM) indicating throttle position.

4. Use three 8T8737 Plug(s) to seal inputs 1, 2, and 3 on the STBD P2 DT connector.

Connecting the PORT Primary Throttle Position Sensor (TPS)


PORT Throttle

1. Connect PIN 5 of the P2 DT Connector to PIN A (+ Battery) of the TPS.

2. Connect PIN 6 of the P2 DT Connector to PIN B (- Battery) of the TPS.

3. Connect PIN 4 of the P2 DT connector to PIN C (throttle) of the TPS.

NOTE: PIN C is the throttle output of the PORT TPS and is a Pulse Width Modulated Signal (PWM) indicating throttle position.

4. Use three 8T8737 Plug(s) to seal inputs 1, 2, and 3 on the PORT P2 DT connector.

Caterpillar Information System:

3400 ELECTRONIC MARINE ENGINES Throttle and Engine Synchronization System
3400 ELECTRONIC MARINE ENGINES 3408 and 3412 High Performance Marine Engine Electronic Control System
G3408 & G3412 ENGINES Testing & Adjusting
G3408 & G3412 ENGINES Systems Operation
ELECTRONIC MODULAR CONTROL PANEL II+ (EMCPII+) FOR MUI ENGIN Testing And Adjusting
ELECTRONIC MODULAR CONTROL PANEL II+ (EMCPII+) FOR MUI ENGIN Systems Operation
VR3F VOLTAGE GENERATOR PERMANENT MAGNET EXCITED SR4 GENERATO Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
VR3F VOLTAGE GENERATOR PERMANENT MAGNET EXCITED SR4 GENERATO Manual Voltage Control
VR3F VOLTAGE GENERATOR PERMANENT MAGNET EXCITED SR4 GENERATO Remote Voltage Control
VR3F VOLTAGE GENERATOR PERMANENT MAGNET EXCITED SR4 GENERATO Bench Test
VR3F VOLTAGE GENERATOR PERMANENT MAGNET EXCITED SR4 GENERATO Problem 4 - Unstable AC Voltage
VR3F VOLTAGE GENERATOR PERMANENT MAGNET EXCITED SR4 GENERATO Problem 3 - High AC Voltage
3400 ELECTRONIC MARINE ENGINES Connecting the PORT and STBD Throttle With Engine Synchronization
3400 ELECTRONIC MARINE ENGINES Trolling Mode
3400 ELECTRONIC MARINE ENGINES Connecting the Diagnostic Connector P3 (DT)
3400 ELECTRONIC MARINE ENGINES Connecting the Transmission Sensors Connector J15 (HD)
3400 ELECTRONIC MARINE ENGINES Optional Computerized Monitoring System (CMS)
3400 ELECTRONIC MARINE ENGINES Connecting the Optional CMS Horn Output
3400 ELECTRONIC MARINE ENGINES Connecting Multiple CMS Displays
3400 ELECTRONIC MARINE ENGINES Connecting the Engine Shutdown Input
3400 ELECTRONIC MARINE ENGINES Installing the RUN/SHUTDOWN Light
3400 ELECTRONIC MARINE ENGINES Relocating the Electronic Control Module (ECM)
3400 ELECTRONIC MARINE ENGINES Electrical System Grounding Requirements
3400 ELECTRONIC MARINE ENGINES Raw Water Connections
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.