Illustration 1 | g01418712 |
(1) Washdown pump and motor group
- Type ... Positive displacement pump
- Nominal voltage ... 25.6 VDC
- Bypass pressure ... 310 kPa (45 psi)
- Nominal voltage ... 25.6 VDC
(2) Apply 5P-3413 Pipe Sealant to the external threads of the adapter.
(3) Apply 5P-3413 Pipe Sealant to the external threads of the fitting.
(4) Apply 5P-3413 Pipe Sealant to the external threads of the elbow.
(5) Apply 5P-3413 Pipe Sealant to the external threads of the connector assembly.
(6) Apply 5P-3413 Pipe Sealant to the external threads of the connector assembly.
(7) Apply 5P-3413 Pipe Sealant to the external threads of the breather.
(8) Clean the mating surface of the tank with 169-5464 Quick Cure Primer .
Note: Use a star pattern to tighten the bolts (9) and perform the sequence for a minimum of two times per pattern.
(9) Torque for the five bolts ... 1.70 ± 0.25 N·m (15 ± 2 lb in)
(10) Apply 5P-3413 Pipe Sealant to the external threads of the adapter.
(11) Apply 5P-3413 Pipe Sealant to the external threads of the drain valve.
(12) Apply 5P-3413 Pipe Sealant to the external threads of the elbow assembly.