To access the "Operator Configuration" dialog, complete the following steps:
- Turn on the Display in Service mode.
- From the "Setup Menu - Configuration" dialog, press "Installation" to list the items under the "Setup Menu - Installation" dialog.
- Press the up arrow or the down arrow until the "Operator Configuration" option is highlighted.
- Press "OK".
The dialog in Illustration 1 appears.
Illustration 1 | g01231964 |
The following information outline the options within the dialog.
"Operator Configuration" Dialog
The "Operator Configuration" dialog shows four branch headings, each with a check box and an expandable tree view. These headings are as follows:
- Configuration
- Installation
- Soft Keys
- Views
Use the check box to enable or disable all the items in a heading. Use the tree view to view and select the individual items below the heading.
"Configuration"
The "Configuration" heading contains a list of items available in the "Setup Menu - Configuration" dialog. Enabling or disabling the items controls how the "Setup Menu - Configuration" dialog appears in Normal mode. In Service Mode, menu items that are disabled in Normal mode are identified by a red "X".
Some of the items under the Configuration heading are subheadings. These subheadings represent Configuration menu items that, when selected, have soft keys or submenus. Edit the items under the subheadings to control what soft keys or submenu items are visible.
"Installation"
The "Installation" heading contains a list of items available in the "Setup Menu – Installation" dialog. Enabling or disabling the items controls how the "Setup Menu – Installation" dialog appears in Normal mode. In Service Mode, menu items that are disabled in Normal mode are identified by a red "X".
Some of the items in the "Installation" heading are subheadings. These subheadings represent Installation menu items that, when selected, have soft keys or submenus. Edit the items under these subheadings to control what soft keys or submenu items are visible.
"Softkeys"
The "Softkeys" heading contains a list of soft keys that appear in the guidance views. It does not include any soft keys from items in the Setup menus. Enabling or disabling items in this heading controls what soft keys are available in Normal mode. In Service Mode, soft keys that are disabled in Normal mode are identified by red text.
Views
The "Views" heading contains the following guidance views:
- Plan
- Profile
- Cross-section
- two text screens
Enabling items or disabling items in the "Views" heading controls what guidance screens are available in Normal mode. In Service Mode, all guidance screens are viewable.
Customizing the Operator Configuration
Press the up arrow or the down arrow in order to select an item in the "Operator Configuration" dialog. If an item is a branch heading, press the left arrow or the right arrow in order to expand or collapse the branch.
To enable or disable an item, select the item and press the soft key that is denoted by a check mark and an "X".
To set the visibility of an item back to the defaults, press the "Default" soft key.
To disable all items in a branch, select the branch heading and press the "Disable All" soft key.
To enable all items in a branch, select the branch heading and press the "Enable All" soft key.
To set all the items back to their default visibility settings, select the branch heading and press the "Default All" soft key.
After using the "Operator Configuration" dialog to customize the display settings, Caterpillar recommends that you save the display settings. Refer to Systems Operation, Testing and Adjusting, Troubleshooting, RENR8088, "Display Settings".