2003/11/10 Caterpillar


Flash Files are Now Available in SIS for Track Feller Bunchers {7620}

Usage:

TK711 101
Track Feller Buncher:
TK711 (S/N: 1011-UP)
TK721 (S/N: 1021-UP)
TK722 (S/N: 1031-UP)
TK732 (S/N: 1041-UP)

The following procedure describes the process that is required to download the software files from SIS and the process that is required to flash the software file to the machine.

Table 1
Required Tools    
Media Number     Description     Quantity    
NETG5037     IQANDevelop     1    

The following components are part of the software kit that is listed above.

  • RS-232 Serial Cable

  • Access Key

  • CD with IQANDevelop Software

Note: The IQANDevelop software on the CD may not be the latest version of the software. You may need to download the IQANDevelop software from the Parker web site.

  1. Access the following web site:

    http://www.parker.com/iqan/

  1. Select "Products" from the menu option.

  1. Select "Software".

  1. Select "IQAN Software G3 with manual ed0337.zip".

Download flash file "2461606.idt" through SIS. There are two different ways to retrieve information from SIS. Information may be accessed through SIS (CD/DVD) or through the SIS (Web).

  1. Go to Step 2 in order to download the flash file from the SIS (web). Go to Step 3 in order to download the flash file from SIS (CD/DVD).



    Illustration 1g01031855

  1. Download the flash file (.idt file) for your machine from the SIS (web).

    1. Go to the web site for SIS.

    1. Type the serial number prefix of your machine in field (1) .

    1. Select "Flash Software Files" (2) .



      Illustration 2g01031861

    1. Type the ".idt" into the "Flash Filename" window (3). Select "Search" (4). This will list all of the ".idt" files.

    1. Place the cursor over "2461606.idt".

    1. Press and hold down the right mouse button. A menu will appear. Move the cursor to the "Save Link As". Release the right mouse button.

    1. The "Save as" menu will appear. Save the file onto your PC.

  1. Use the following procedure to download the flash files from SIS (CD/DVD).

    1. Insert the SIS (CD/DVD) into your computer.

    1. View the contents of the SIS (CD/DVD). Select the "Readxref.txt" file in order to view a complete listing of all flash documents that can be used to identify the proper flash file for your application.

    1. Save the file to your PC.



    Illustration 3g01031878

  1. Connect the serial cable between your PC and the IQAN system connection on your machine.

    1. Remove two screws (5) .

    1. Flip the IQAN-MDM downward.



      Illustration 4g01031909

    1. Connect the serial cable between your PC and IQAN system connection (6) .

  1. Turn the engine start switch key to the ON position in order to activate the IQAN system on your machine.

  1. Retrieve the flash file (.idt file) that was downloaded and saved to your PC by selecting "Open" from the "File" menu.

  1. Select "Send application" from the "System" menu. The following window will appear.



    Illustration 5g01031915

    Note: Use the settings that are shown in the Illustration above. See the following "Definitions" for a description of each selection.

  1. Select "Send" (7) in order to send the application.

    (A) Use this setting in order to keep the settings for your adjustable values. However, you will not see the new enhancements and settings of the file that was flashed until you reset your "driver mode". See your Operation and Maintenance Manual, "Reset Mode".

    (B) Use this setting in order to use the new enhancements and settings from the factory. Your "driver modes" will be automatically reset to the factory settings of the file that was flashed.

  1. A message screen will show the download in progress.

Definitions

Note: Errors must be corrected before the application can be sent. To communicate with the master, the lamp in the status area must give a green light.

"Factory Default Values"

"Leave values in master unchanged" - This leaves the factory default values in the master unchanged.

"Use values from IQANdevelop application" - This replaces the factory default values in the master with the values that is specified in the application. This is the default option.

"Adjustable Values"

"Leave values in master unchanged" - This leaves the factory default values in the master unchanged. This is the default option.

"Use values from IQANdevelop application" - This replaces the factory default values in the master with the values that are specified in the application.

Factory Default Value or Adjustable Value

The factory default value corresponds to the original values of the application. When you send the application to the master, the factory default values will be stored in an area that is write protected in the memory of the master. When you adjust a channel, the "factory default values" will not be affected. Only the adjustable values will be affected. The channels that enabled the adjustable values use the adjustable values. The other channels use the factory default values. The operator can always reset an adjustable value to the corresponding factory default value.

"Stored Values"

  • "Hour counter"

  • "Event counter"

  • "Memorizing"

"Leave values in master unchanged" - This leaves the stored values in the master unchanged. This is the default option. Use this option when you are updating an application.

"Use values from IQANdevelop application" - This replaces the stored values in the master with the values that are specified in the application. You cannot set stored values manually in IQANdevelop. However, you can retrieve the stored values from another master module by getting the application. Use this option to move the stored values from one master to another master. This is done when you must exchange the master module in a machine.

"Reset all values in master to zero" - This resets all stored values to zero.

Caterpillar Information System:

247B and 257B Multi Terrain Loaders Machine Systems Bogie Wheel
TH220B and TH330B Telehandlers Power Train Transmission and Torque Converter - Install
2004/06/07 A New Track Roller is Available for the Cold Planer {4180}
2005/02/21 A Clamp Increases the Sealing Capability of the Coolant Bypass Tube {1380}
2003/12/01 Arctic Cartridge Pins Are Available {7217}
2003/12/01 New Fuel Filter Base Has Been Released {1262}
416D, 420D, 424D, 428D, 430D, 432D and 442D Backhoe Loaders Brake Reservoir Oil Level - Check
789C Off-Highway Truck Daily Inspection
2004/02/23 Correction to Disassembly and Assembly , "Tandem and Cover - Remove and Install" {4064}
3508B Engine for Caterpillar Built Machines Elevated Low Idle Operation
2004/02/23 Correction to Disassembly and Assembly , "Tandem and Cover - Remove and Install" {4064}
3512 and 3516 EUI Engines for Caterpillar Built Machines Elevated Low Idle Operation
R2900G Load Haul Dump Braking System Brake Release Cylinder
R1600G Load Haul Dump Power Train Electronic Control System MID 081 - CID 0679 - FMI 03
R1600G Load Haul Dump Power Train Electronic Control System MID 081 - CID 0679 - FMI 05
R1600G Load Haul Dump Power Train Electronic Control System MID 081 - CID 0679 - FMI 06
R2900G Load Haul Dump Braking System Pressure Switch (Residual Brake Oil)
R1600G Load Haul Dump Power Train Electronic Control System MID 081 - CID 0668 - FMI 02
R2900G Load Haul Dump Braking System Sequence Valve (Brake Release)
R1600G Load Haul Dump Power Train Electronic Control System MID 081 - CID 0687 - FMI 02
247B, 257B, 267B, 277B and 287B Multi Terrain Loaders and 216B, 226B, 232B, 236B, 242B, 246B, 248B, 252B, 262B and 268B Skid Steer Loaders Auxiliary Hydraulic Electronic Control System System Schematic
416D, 420D, 424D, 428D, 430D, 432D and 442D Backhoe Loaders Equipment Lowering with Engine Stopped - Pilot Controls
2003/11/03 Correction to Disassembly and Assembly, RENR5186 , "Tire and Rim - Remove and Install" {4202}
584 and 584HD Forwarders Guards - Operator Protection