Alternator - Delco 27SI Caterpillar


Regulator - Test

Usage:

D6D 01Y
The regulator test determines problems in the following components: the regulator, the field winding, the rectifier and the diode assembly. The regulator test does not cover all failures.



    Illustration 1g00870247

    Regulator Test

  1. Connect a variable power supply (VPS) and two multimeters to the alternator. The alternator is completely assembled for this test. Set one multimeter as a voltmeter (V). Set the other multimeter as an ammeter (A). The setup is shown in Illustration 1.

  1. Set the variable power supply to 0 volts. Slowly raise the power supply until the ammeter indicates a current draw.

  1. Measure the voltage. Record the result as the "Turn On" voltage.

    Expected Results:

    3T-6352 Alternator Gp ... 27.4 ± 0.6 volts
    5N-5692 Alternator Gp ... 27.4 ± 0.6 volts
    7G-7889 Alternator Gp ... 14.0 ± 0.3 volts

    Results:

    OK - The voltage is within tolerance. Go on to Step 4.

    NOT OK - The voltage is not within tolerance. The regulator has failed. Replace the regulator. STOP.

  1. The regulator remains on. Measure the current. Record the result as the field current.

    Expected Results:

    3T-6352 Alternator Gp ... 3.3 to 3.8 amperes
    5N-5692 Alternator Gp ... 2.5 to 2.8 amperes
    7G-7889 Alternator Gp ... 5.7 to 7.1 amperes

    Results:

    OK - The current is within tolerance. Go on to Step 5.

    NOT OK - The current is below tolerance or the current is 0 amperes. The field winding, the rectifier, or the regulator is open. Refer to Testing and Adjusting, "Field Winding - Test" and Testing and Adjusting, "Rectifier - Test". If the field winding is open, replace the field winding. If the rectifier is open, replace the rectifier. If the field winding and the rectifier are normal, the regulator is open. Replace the regulator. STOP.

    NOT OK - The current is above tolerance. The field winding has a short circuit. Replace the field winding. Go on to Step 5.

  1. Divide the "Turn On" voltage by the rotor field winding resistance. Refer to Specifications, "Alternator" for the rotor field winding resistance. Record the result as the field current. Compare the current that was calculated above with the current that was measured in Step 4. The values should agree.

  1. The power supply remains at the "Turn On" voltage. Slowly raise the voltage until the ammeter reads 0 amperes. Record the result as the "Turn Off" voltage.

    Note: The ammeter should drop quickly to 0 amperes. If the ammeter drops slowly, the regulator has failed.

  1. Subtract the "Turn On" voltage from the "Turn Off" voltage.

    Expected Result: The difference is 0.3 volts or less.

    Results:

    OK - The difference is 0.3 volts or less. The regulator is normal. STOP.

    NOT OK - The difference is greater than 0.3 volts. The regulator has failed. Replace the regulator. STOP.

Caterpillar Information System:

3512B Engine for SPF343, SPS343, and SPT343 Pumpers System Overview
3126B Truck Engine Engine Lifting
C32 Power Module Generator Set Installation
3406E, C12, C15 and C18 Marine Engines Excessive Black Smoke
3176C and 3196 Engines for Caterpillar Built Machines Engine Misfires, Runs Rough or Is Unstable
PMG3516 Power Module Insulation - Test
3508, 3512, and 3516 Generator Sets Bearing - Inspect - Generator
C15 and C18 Petroleum Generator Sets Generator Start-up Checklist
N3 Series Brushless Alternators Alternator - Disassemble
N3 Series Brushless Alternators Alternator - Assemble
3406E, C12, C15 and C18 Marine Engines Engine Cranks but Will Not Start
PMG3516 Power Module Generator Lead Connections
3126B Marine Engines Intermittent Engine Shutdown
3406E, C12, C15 and C18 Marine Engines Intermittent Low Power or Power Cutout
3406E, C12, C15 and C18 Marine Engines Low Power/Poor or No Response to Throttle
3500 Generator Set Engines Tachometer Drive
3126B Marine Engines Poor Acceleration or Response
2002/03/01 WEB Sites Are Available On The Internet For Products That Are Manufactured At The Large Engine Center {1000}
3500 Industrial Engines Signal Generator
3512B Petroleum Engines with the ADEM 2 Electronic Control Module Engine Misfires, Runs Rough or Is Unstable
3512B Engine for SPF343, SPS343, and SPT343 Pumpers Engine Will Not Crank
2002/03/01 New Engine Oil Heater Groups Are Available And New Coolant and Engine Oil Heater Groups Are Available {1333, 1383}
3500 Industrial Engines Power Take-Off Clutch
3500 Industrial Engines Power Take-Off Clutch
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.