C7.1 Marine Generator Set Caterpillar


Electrical System

Usage:

C7.1 JME
The electrical system is an insulated ground system.

The charging circuit operates when the engine is running. The alternator in the charging circuit produces direct current for the electrical system.

Starting Motor




Illustration 1g01964824

Typical example

12 V 4 kW Starting Motor

(1) Terminal 30 for connection of the battery cable

(2) Terminal 50 for connection of ignition switch

(3) Terminal 31 for connection of the ground




Illustration 2g01964833

Typical example

24 V 5.5 kW Starting Motor

(4) Terminal 30 for connection of the battery cable

(5) Integrated Magnetic Switch (IMS)

(6) Terminal 50 for connection of ignition switch

(7) Terminal 31 for connection of the ground




Illustration 3g01964823

Typical example

24 V 8 kW Starting Motor

(8) Terminal 30 for connection of the battery cable

(9) Integrated Magnetic Switch (IMS)

(10) Terminal 50 for connection of ignition switch

(11) Terminal 31 for connection of the ground

The starting motor turns the engine via a gear on the engine flywheel. The starting motor speed must be high enough in order to initiate a sustained operation of the fuel ignition in the cylinders.

The starting motor consists of the main armature and a solenoid. The solenoid is a relay with two windings Pull-In (PI) and Hold-In (HI). Upon activation of ignition switch, both windings move the iron core by electromagnets. The linkage from the iron core acts to move the pinion toward the flywheel ring gear for engagement. Upon complete engagement, the solenoid completes the high current circuit that supplies electric power to the main armature in order to provide rotation. During cranking of the engine, only the Hold-In (HI) winding is active.

The ignition switch is deactivated once the desired engine speed has been achieved. The circuit is disconnected. The armature will stop rotating. Return springs that are located on the shafts and the solenoid will disengage the pinion from flywheel ring gear back to the rest position.

The starting motor has an overrunning clutch to prevent damage to the starting motor and mechanical transmissions as the engine speed increases.

Certain higher powered starting motors are designed with an Integrated Magnetic Switch (IMS). The Integrated Magnetic Switch (IMS) is activated by the ignition switch. The solenoid circuit then engages the starting motor. The benefit of Integrated Magnetic Switch (IMS) is a lower current in the ignition circuit that will allow the engine ECM to control ignition without the use of a relay.

Air Starting Motor




Illustration 4g01675493

Typical example

The air starting motor is a nonserviceable component. The correct air supply must be provided to the air starting motor. Refer to Specifications, "Air Starting Motor" for more information.

Alternator

The electrical outputs of the alternator have the following characteristics:

  • Three-phase

  • Full-wave

  • Rectified

The alternator is an electro-mechanical component. The alternator is driven by a belt from the crankshaft pulley. The alternator charges the storage battery during the engine operation.

The alternator is cooled by an external fan which is mounted behind the pulley. The fan may be mounted internally. The fan forces air through the holes in the front of the alternator. The air exits through the holes in the back of the alternator.

The alternator converts the mechanical energy and the magnetic field into alternating current and voltage. This conversion is done by rotating a direct current electromagnetic field on the inside of a three-phase stator. The electromagnetic field is generated by electrical current flowing through a rotor. The stator generates alternating current and voltage.

The alternating current is changed to direct current by a three-phase, full-wave rectifier. Direct current flows to the output terminal of the alternator. The direct current is used for the charging process.

A regulator is installed on the rear end of the alternator. Two brushes conduct current through two slip rings. The current then flows to the rotor field. A capacitor protects the rectifier from high voltages.

The alternator is connected to the battery through the ignition switch. Therefore, alternator excitation occurs when the switch is in the ON position.

Caterpillar Information System:

C7.1 Marine Generator Set V-Belt - Test
C7.1 Marine Generator Set Glossary of Electronic Control Terms
G3606 and G3608 Engines Air Starting Motor - Remove and Install
Components May Be Assembled Incorrectly in the 0R-3037 Cylinder Pack As {1225} Components May Be Assembled Incorrectly in the 0R-3037 Cylinder Pack As {1225}
C280 Marine Engines Injector Solenoid - Test
C7.1 Marine Generator Set Fuel System - Prime
2015/06/05 The Prelube System Pressure Switch Is Missing on Certain G3500 Engines {7400}
G3612 and G3616 Engines Engine Oil Pan - Remove and Install
2015/03/31 New Heat Exchanger Group Is Now Introduced on Certain C32 Generator Sets {1379}
C7.1 Marine Generator Set Introduction
C2.2 Engines for Caterpillar Built Machines Cleanliness of Fuel System Components
® Marine Display Three60 Precision Control Screen
C7.1 Marine Generator Set Air Inlet and Exhaust System
C7.1 Marine Generator Set Cooling System
C7.1 Marine Generator Set Fuel Injection
C7.1 Marine Generator Set Electronic Control System
C7.1 Marine Generator Set Turbocharger - Inspect
C7.1 Marine Generator Set Cooling System - Check - Overheating
C7.1 Marine Generator Set Power Sources
2015/03/31 Updated Torque Requirements for Reman Rocker Arm Adjusting Screw Lock Nuts on Certain C15, C18, C27, and C32 Machine Engines {1123}
2015/04/03 Updated Torque Requirements for Reman Rocker Arm Adjusting Screw Lock Nuts on Certain C15, C16, C18, C27, and C32 Engines {1123}
2015/04/10 Updated Torque Requirements for Reman Rocker Arm Adjusting Screw Lock Nuts on Certain C15, C16, and C18 Truck Engines {1123}
G3612 and G3616 Engines Oil Temperature Regulators - Remove and Install
C9.3 Marine Auxiliary and Generator Set Engine Exhaust System Contains Coolant
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.