Boost Pressure Is High
Use this procedure in order to troubleshoot a high boost pressure or use this procedure if the following diagnostic code is active. Access the monitoring system on the Cat® Electronic Technician (ET) in order to view the current trip points for this code.
Show/hide table
Diagnostic Code | |||
---|---|---|---|
Code and Description | Flash Codes | Default Conditions which Generate this Code | System Response |
102-00 Boost Pressure Sensor : High | 25 | The boost pressure is above the trip point for high boost pressure. | The code is logged. |
- Excessive engine load
Show/hide table
Troubleshooting Test Steps | Value | Results |
---|---|---|
1. Excessive Load On the Engine. |
Engine Load |
Result : There is excessive load on the engine. Repair : Reduce the load on the engine to an acceptable range. |
Caterpillar Information System:
3412 Generator Set Acceleration Is Poor or Throttle Response Is Poor
C9.3 Marine Engines Exhaust Temperature Sensor
C18 Generator Set Generator Start-up Checklist
C18 Generator Set Refill Capacities
3516C Marine Engines Crankshaft - Remove and Install
G3500H 60Hz Generator Sets Starting Motor - Inspect
C18 Generator Set Voltage Regulators
C9.3 Marine Propulsion Engine Coolant Temperature Is High
C7.1 Engines Indicator Lamp Problem
C18 Generator Set Generator Lead Connections
C4.4 and C7.1 Engines Cooling Fan - Calibrate - If Applicable
2015/04/08 New Hydraulic Hoses Are Available for TH55-E70 and TH55-E90 Petroleum Transmissions {1375, 3016, 3154}
G3612 and G3616 Engines Air Inlet Elbow - Remove and Install
3412 Generator Set Boost Pressure Is Low
3412 Generator Set Coolant Temperature Is High
2015/02/20 Top End and Major Overhaul Foundational Kits Are Available for 3508 Petroleum Engines {1000}
2015/02/20 Top End and Major Overhaul Foundational Kits Are Available for 3516 Electric Power Engines {1000}
3412 Generator Set Coolant Temperature Is Low
3412 Generator Set Engine Cranks but Does Not Start
3412 Generator Set Engine Does Not Crank
C4.4 Generator Sets Generator Operation
3412 Generator Set Engine Misfires, Runs Rough or Is Unstable
3412 Generator Set Engine Overspeeds
794 AC Off-Highway Truck Brakes, Indicators and Gauges - Test