G3306B Generator Sets Caterpillar


Generator Bearing Temperature - Test/Record

Usage:

XQG135 AL4
The monitoring of bearing temperature may prevent premature bearing failure. A generator set should never operate above the recommended set points. Keep records in order to monitor the changes in the temperature of the bearing.

Note: Measure the bearing temperature after the generator reaches normal operating temperature.

Resistive Temperature Detectors (RTDs)

Cat Generators may be equipped with resistance temperature detectors for generator bearings. These detectors are 100 ohm resistance temperature detectors. A resistance temperature detector may be monitored by the optional monitor for the EMCP 4.4 resistance temperature detector. A resistance temperature detector may be monitored by equipment that is provided by the customer. Consult with your Cat dealer about other methods of measuring the bearing temperature.

The EMCP 4.4 may be configured to "ALARM" or the EMCP 4.4 may be configured to "SHUTDOWN". An alarm is activated if the temperature of the bearing reaches 85 °C (185 °F). A shutdown occurs if the temperature of the bearing reaches 95 °C (203 °F).

Infrared Thermometers

Bearing temperatures can also be recorded with the use of an infrared thermometer. Refer to Special Publication, NENG2500, "Cat Dealer Service Tools Catalog" for various infrared thermometers. Follow the instructions that come with your infrared thermometer.

Caterpillar Information System:

C9 Engine For Caterpillar Built Machines Turbocharger - Assemble
G3306B Generator Sets Generator - Dry
3512C HD and 3516C HD IPP Rental Power Modules Crankcase Pressure Is High
C4.4 Engines for Caterpillar Built Machines Gear Group (Front) - Remove and Install
G3306B Generator Sets Gas Pressure Regulator - Test
G3306B Generator Sets Control Panel - Inspect/Test
390F Excavator Machine Systems Bucket Cylinder - Remove and Install
3512C HD and 3516C HD IPP Rental Power Modules Coolant Temperature Is Low
XQC1600 Power Module General Maintenance Information
3512C HD and 3516C HD IPP Rental Power Modules Coolant Temperature Is High
G3306B Generator Sets Manual Stop Procedure
3512C HD and 3516C HD IPP Rental Power Modules Coolant Level Is Low
2014/12/12 A New Turbine Outlet Bellows Assembly Is Used On Certain 3500 Commercial Engines {1061, 1065}
G3306B Generator Sets Electronic Modular Control Panel 4 (EMCP 4) - EMCP 4.4
C175-16 Petroleum Generator Set Engines Engine Air Cleaner Element - Replace
C175-16 Marine Engines Thermostatic Valve - Inspect
3512C HD and 3516C HD IPP Rental Power Modules Engine Overspeeds
DE Series Generator Set With Cat C4.4 Engine Cold Weather Operation
DE Series Generator Set With Cat C4.4 Engine Plate Locations and Film Locations
DE Series Generator Set With Cat C7.1 Engine Fuel System Primary Filter (Water Separator) Element - Replace
DE Series Generator Set With Cat C7.1 Engine Fuel System Secondary Filter - Replace
DE Series Generator Set With Cat C7.1 Engine Fuel Tank Water and Sediment - Drain
DE Series Generator Set With Cat C7.1 Engine Hoses and Clamps - Inspect/Replace
DE Series Generator Set With Cat C4.4 Engine Water Pump - Inspect
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.