Introduction
In order to achieve proper shunt line pressure in balance with engine venting, only certain water pump inlet connection ports should be used. Alternatively, shunt lines may also be connected to the pipe that carries coolant from the radiator to the engine water pump inlet or to the radiator bottom tank.
The diagrams below show the proper connection port.
Illustration 1 | g03570838 |
Testing
A new test procedure (Air Entrainment Test) is available to evaluate proper operation of the shunt tank and lines. This test procedure will determine if the cooling system shunt and vent flows are properly balanced.
For the test procedure, Refer to Application and Installation, LEBH0003 and Application and Installation, LEBH0012.
Contact the Application Support Center (ASC) for further assistance.
C9.3 Acert Shunt Line Connection at Pump
Illustration 2 | g03570582 |
(1) Acceptable Port |
278-0245 Elbow
C13 Acert Shunt Line Connection at Pump
Illustration 3 | g03570656 |
(1) Acceptable port (2) Unacceptable port |
332-2376 Water Pump Elbow
Illustration 4 | g03570698 |
(2) Unacceptable port |
255-2395 Water Pump Elbow
Illustration 5 | g03570917 |
(2) Unacceptable port |
330-4611 Water Pump Cover and 252-2685 Elbow
C15 Acert / C18 Acert Shunt Line Connections at Pump
Illustration 6 | g03571016 |
(1) Acceptable port (2) Unacceptable port |
341-4177 Water Pump Cover
Illustration 7 | g03571017 |
(1) Acceptable port (2) Unacceptable port |
196-4813 Water Pump Cover
Illustration 8 | g03571018 |
(1) Acceptable port (2) Unacceptable port |
369-7512 Water Pump Cover
Illustration 9 | g03571020 |
(1) Acceptable port (2) Unacceptable port |
161-3565 Water Pump Cover
C27 Acert / C32 Acert and 3412 Shunt Line Connections at Pump
Illustration 10 | g03571256 |
(1) Acceptable port (2) Unacceptable port |
346-5786 Water Pump Cover
Illustration 11 | g03571257 |
(1) Acceptable port (2) Unacceptable port |
237-4180 Water Pump Cover
Illustration 12 | g03571259 |
(1) Acceptable port (2) Unacceptable port |
4P-3864 Water Pump Cover