Aftercooler
Show/hide table
Illustration 1 | g03201799 |
(1) Air inlet (2) Coolant inlet (3) Coolant outlet (4) Aftercooler cores (5) Air outlet |
The aftercooler is located at the center of the vee. The aftercooler has a core assembly that is charged by the coolant. Coolant from the water pump flows through a pipe into the aftercooler and through the aftercooler core assembly. Coolant flows back out the aftercooler through a different pipe.
Inlet air from the compressor side of the turbochargers flows into the aftercooler through pipes. The air then passes through the fins of the core assembly, which lowers the temperature. The cooler air flows out of the bottom of the aftercooler and into the air chamber. The air flows through the elbows to the inlet ports in the cylinder heads.
Caterpillar Information System:
3516B and 3516C Engines For MT4400D AC Off-Highway Trucks Air Inlet and Exhaust System
3516B and 3516C Engines For MT4400D AC Off-Highway Trucks Fuel System
G3500 Engines Gear Group (Rear)
G3500 Engines Gear Group (Rear)
330F MHPU Mobile Hydraulic Power Unit Machine System Hydraulic Tank and Filter
C175-16 Locomotive Engine Fuel Transfer Pump - Install
G3516 Engines Accessory Drive (Lower Left Hand)
2012/12/06 A New Outlet Elbow Is Used with the Oil Cooler Adapter on Certain 3516B and 3516C Engines {1380}
G3500 Engines Cylinder Head Valves
C7.1 Marine Generator Set Control Panel - Marine Classification Society (MCS) Control Panel (If Equipped)
G3500 Engines Cylinder Head Valves
G3500 Engines Stub Shaft (Front)
C175-16 Locomotive Engine High Pressure Fuel Rails - Remove and Install
C13 Tier 4 Final Engines Turbocharger - Inspect
3516B and 3516C Engines For MT4400D AC Off-Highway Trucks Electrical System
C7.1 Marine Generator Set Belt - Inspect
C7.1 Marine Generator Set Belt Tensioner - Check
C175-16 Locomotive Engine Flow Limiter - Remove and Install
C8.7 Marine Engines Inlet Manifold Pressure - Test
3500 Generator Sets with Dynamic Gas Blending Safety Messages
C175-16 Locomotive Engine Fuel Control Valve - Remove and Install - Primary
C175-16 Locomotive Engine Fuel Pump (High Pressure) - Remove and Install
C175-16 Locomotive Engine Coolant Temperature Control Module - Test
3500 Generator Sets with Dynamic Gas Blending Refill Capacities