TA19 and TA22 Transmissions Power Train Electronic Control System Caterpillar


Transmission, SPN 739 - FMI 6

Usage:

TA19-M4WD XAE
Conditions Which Generate This Code:


Illustration 1g02608758
Connections of the transmission clutch solenoid 6

Note: THE HARNESS BETWEEN THE ECM AND THE OEM CONNECTOR IS NOT A CATERPILLAR HARNESS. FOR MORE INFORMATION ABOUT THIS HARNESS PLEASE CONTACT THE OEM MANUFACTURER.

This diagnostic code is associated with the transmission clutch solenoid 6. The FMI 6 means that the ECM has determined that there is a short to ground in the solenoid circuit.

The possible causes of this diagnostic code are listed:

  • The energize circuit of the solenoid is shorted to ground.

  • The solenoid has failed.

  • The ECM has failed. An ECM failure is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 739 FMI 6 is active before performing this procedure.

Note: Use a digital multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  2. Observe the status of the diagnostic code.

  3. Disconnect the solenoid with the active diagnostic code from the machine harness.

Expected Result:

The FMI 6 changes to FMI 5 when the solenoid is disconnected.

Results:

  • YES - The FMI 6 changes to FMI 5 when the solenoid is disconnected. The circuit is correct.

    Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

  • NO - The SPN 739 FMI 6 remains active. Proceed to Test Step 2.

Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  2. The solenoid remains disconnected from the machine harness.

  3. Disconnect the machine harness connectors from the ECM.

  4. At the machine harness connector, measure the resistance from the signal contact J1-59 to all other contacts that are used in the machine harness connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-59 and the circuit with the low resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation caused by excessive heat, battery acid, or chafing.

  2. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  3. Reconnect all harness connectors. Make sure that the harness connectors are fully seated and that the clips for each connector are fastened.

  4. Turn the disconnect switch and the key start switch to the ON position.

  5. Operate the vehicle.

  6. Check the status of the SPN 739 FMI 6.

Expected Result:

The SPN 739 FMI 6 is active.

Results:

  • YES - The SPN 739 FMI 6 is active. The diagnostic code has not been corrected.

    Repair: Check the circuit again. If the Caterpillar Electronic Technician (Cat ET) is available, use the Cat ET service tool in order to perform a “Wiggle Test” on the machine wiring harness. The “Wiggle Test” can detect shorts and opens in the machine wiring harness that are momentary or intermittent.

    An ECM failure is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The SPN 739 FMI 6 is not active. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal vehicle operation.

    STOP

Caterpillar Information System:

TA19 and TA22 Transmissions Power Train Electronic Control System Wiring Harness (Short Circuit) - Test
TA19 and TA22 Transmissions Power Train Electronic Control System Wiring Harness (Open Circuit) - Test
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission Fill - Calibrate
TA19 Agriculture Transmission Electronic Control System System Schematic
561N, 572R Series II and 572R Pipelayers and D10R, D11R, D5M, D5N, D6M, D6N, D6R, D6R Series II, D7R, D7R Series II and D8R Series II Track-Type Tractors Power Train Electronic Control System Service Tools
TA19 Agriculture Transmission Electronic Control System Machine Preparation for Troubleshooting
TA19 and TA22 Transmissions Power Train Electronic Control System Inching Pedal - Calibrate
793F CMD Off-Highway Truck/Tractor Braking System Electronic Control Module (ECM) - Replace
TA19 and TA22 Transmissions Power Train Electronic Control System Electronic Control Module (ECM) - Flash Program
Do Not Use Unapproved Connecting Rod 7N-2405 Bolts for 3500 and G3500 Engines{1225, 7553} Do Not Use Unapproved Connecting Rod 7N-2405 Bolts for 3500 and G3500 Engines{1225, 7553}
TA19 Agriculture Transmission Electronic Control System Electrical Connector - Inspect
854K Wheel Dozer and 992K Wheel Loader Power Train Diagnostic Capabilities
C27 and C32 Engines for Caterpillar Built Machines Electronic Unit Injector Wiring
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission, SPN 739 - FMI 5
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission, SPN 1079 - FMI 3
TA19 Agriculture Transmission Electronic Control System Transmission, SPN 1079 - FMI 4
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission, SPN 739 - FMI 3
320E, 320F, 323E, 323F, 324E, 326F, 329E, 329F and 330F Excavators Tool Control System Combined Function - Electric Control
TA19 Agriculture Transmission Electronic Control System Transmission, SPN 127 - FMI 3
TA19 Agriculture Transmission Electronic Control System Transmission, SPN 127 - FMI 4
TA19 Agriculture Transmission Electronic Control System Transmission, SPN 161 - FMI 2
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission, SPN 177 - FMI 3
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission, SPN 177 - FMI 4
TA19 and TA22 Transmissions Power Train Electronic Control System Transmission, SPN 191 - FMI 12
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.