Accessing Calibrations For The Transmission Solenoid Valves
Calibration is required when one of the following conditions occur:
- The component has been replaced.
- The ECM has been replaced.
- Normal wear on a component
- Physical alteration of the component or the linkage
Service Tools | |
Caterpillar Electronic Technician (ET) |
The Caterpillar Electronic Technician service tool (ET) is used to access the calibration procedures. A message on the ET screen will give instructions that guide the user through the calibration procedure. Refer to the Manual that is provided with the ET for more information.
- Connect the ET to the tractor.
Once communication has been established, the ET will list the electronic control modules that are on the tractor.
- Select "Service" from the menu bar.
Show/hide table
Illustration 1 g01347536 ET Screen of the Calibration Menu for Transmission ECM - Select "Calibrations" from the drop-down menu ("Service").
Another drop-down menu will appear. The menu will list each available calibration.
- Select "Transmission Fill Calibration".
- Follow all instructions on the ET in order to complete the calibration procedures.
Note: Calibration will require certain conditions to be set prior to the start of the calibration. For example, set the shift lever to PARK. The user must ensure that all the setups for the conditions of the calibration are satisfied.