Illustration 1 | g03891305 |
(A) Water pump On/Off indicator (Green/On, Red/Disabled)
(B) Water cannon (Green/Enabled, Red/Disabled) (C) Light/Heavy spray indicator (D) Water level indicator (E) Flow Rate indicator (1) Spray head # 1 (Green/Enabled, Red/Disabled) (2) Spray head # 2 (Green/Enabled, Red/Disabled) (3) Spray head # 3 (Green/Enabled, Red/Disabled) (4) Spray head # 4 (Green/Enabled, Red/Disabled) (5) Spray head # 5 (Green/Enabled, Red/Disabled) (6) Spray head # 6 (Green/Enabled, Red/Disabled) Note: Machines equipped with Tire Fire (TF) configuration mount head # 6 for fire suppression. Machines equipped with Straight Line (SL) configuration mount head # 6 as an additional rear spray head. (7) Spray head # 7 (Green/Enabled, Red/Disabled) |
Note: Spray heads will not light up green unless there is water in the tank. Spray heads will not appear on the screen, if spray heads are not available.
Home Screen Menu
Use Back Button to return to previous screen |
|||
---|---|---|---|
"F2" | Water Pressure Sensor | Green/Normal
Red/Failure |
|
Tank Level Sensor | |||
Hydraulic Oil Temperature | Press "F1" to reset a High Hydraulic Temp Shutdown | ||
Hydraulic Oil Pressure Sensor | |||
"F3" | Diagnostic Screen | Low Hydraulic Oil | "F1" to clear diagnostics
"F3" to reset hydraulic oil temperature |
Low Water Pressure Off | |||
Hydraulic System Pressure High | |||
High Hydraulic Oil Temperature | |||
Dirty Hydraulic Filter | |||
"F4" (Mode menu) Default PIN Code: 1***(1) | Tank Lift | Lift Tank | Tank Mode must be Enabled in the Adjust submenu and the tank must be empty |
Float Tank | |||
Lower Tank | |||
Hold Tank | |||
Units | English | ||
Metric | |||
Hour Meter Page | Hour Data | ||
Head Reset Page (reset hour meter on corresponding spray heads and pump) |
(1) | Contact your Cat dealer for PIN code support. |
Illustration 2 | g02584697 |
Main Menu
From the Home Screen, press the Menu button to access the Main Menu Use Back button (left arrow) to return to previous screen Use Up/Down buttons to make selection Use "OK" button to confirm selection |
|||||
---|---|---|---|---|---|
Submenu(s) | Parameter
Reset will return an individual parameter to the default setting |
Default PIN Code(1) | |||
Adjust | Setup | Truck model | Select Model | 1*** | |
Spray Configuration Set Up | Setup (spray head arrangement) | ||||
Tank Lift option | Disabled/Enable | ||||
Cannon Install option | Not installed/Installed | ||||
Auxiliary Install option | Not Installed/Dump Bar/Hose Reel | ||||
Tank Fill option | Momentary Single, Maintain Single, Momentary Dual not installed | ||||
Manual Mode Enable | Disabled/Enabled | ||||
Manual Mode Deactivation | 0 - 40 KPH | ||||
Intermittent Mode Enable | Disabled/Enabled | ||||
Config Change PIN code | Change PIN | ||||
Mode Change PIN code | Change PIN | ||||
Manual PIN code Change | Change PIN | ||||
Intermittent PIN code Change | Change PIN | ||||
Adjust (continued) | Spray Head Calibration | 2-5 Spray Head Calibration | Select Disabled or Enabled | 2*** | |
(Optional) 167 Head Calibration Active | Select Disabled or Enabled | ||||
Cannon Head Speed Adjust | L/R Joystick Speed Adjust | Left/Right
1 = default 1 > less power 1 < more power |
1*** | ||
U/D Joystick Speed Adjust | Up/Down | ||||
L Joystick Sensitivity | |||||
R Joystick Sensitivity | |||||
U Joystick Sensitivity | |||||
D Joystick Sensitivity | |||||
Adjust (continued) | config # 1 - 7
(This submenu available only if the corresponding preset number on the keypad is selected prior to accessing the Adjust screen) |
Head # Enable/Disable (Select desired spray heads | 1 = enabled, 0 = disabled
Press OK to confirm the selection. The selection must be confirmed before a change will occur. |
1*** | |
Minimum Spray speed (Default is 4.8 km/h (3 mph)) | 1.6 km/h (1 mph)
-8 km/h (5 mph) |
||||
Light/Heavy Config # | Select Light or Heavy spray for each corresponding configuration number | ||||
Intermittent
(2) |
1 = enabled, 0 = disabled
Press OK to confirm the selection. The selection must be confirmed before a change will occur. |
||||
Flow Default Rate | -4 to +4
- Less + More |
||||
Adjust (continued) | Tank Properties | Low Water Level Shut Off Valve | Actual value [%] # | 1*** | |
Empty Tank Value | Actual value [%] # | ||||
Tank Full Shut Off % | Actual value [%] # | ||||
Low Water Warning Value | Actual value [%] # | ||||
Tank Full Value | Actual value [%] # | ||||
Distance Intermittent | Distance | Distance On/Off | |||
Time | Time On/Off | ||||
Intermittent Spraying Mode | Intermittent On Value (SEC) | Actual value [SEC] # | 1*** | ||
Intermittent Off Value (SEC) | Actual value [SEC] # | ||||
Intermittent Time/Distance | |||||
Oncoming Traffic | Head 1 Oncoming Block | On/Off | 1*** | ||
Head 2 Oncoming Block | On/Off | ||||
Head 3 Oncoming Block | On/Off | ||||
Head 4 Oncoming Block | On/Off | ||||
Head 5 Oncoming Block | On/Off | ||||
Head 6 Oncoming Block | On/Off | ||||
Head 7 Oncoming Block | On/Off | ||||
Dimmer | Switch Dimmer | Actual value # | 1*** | ||
Tank Lift | Tank Lift Enable | 1 = Yes, 0 = No | 7*** | ||
Measure | Joystick | Refer to Specifications / System Operation / Testing and Adjusting / Disassembly and Assembly / Troubleshooting, UENR2065, UENR3561, and UENR3533, "Water Delivery System". | No PIN Code | ||
Key Pad | |||||
Cannon | |||||
Tank Level | |||||
Hydraulic Tank Sensors | |||||
Spray Heads | |||||
Pressure checks | |||||
Head Intensity Settings | |||||
Hydraulic Pressure REG | |||||
Preferences | Display | Backlight | 10 - 100 | No PIN Code | |
Screen Saver | Off | Dimmed Light (Dimmed only) 0-90
Timeout (Dimmed and Black) 5 -600 |
|||
Dimmed | |||||
Black | |||||
Date/Time | Date | Set | |||
Time | |||||
Language | English | Set | |||
Spanish | |||||
Portuguese | Set | ||||
French Canadian | Set | ||||
Info | Machine ID | WDS hardware serial number | No PIN Code | ||
Modules | WDS
Rear Mount Front Mount Key Pad Joystick Truck Data in cab |
Module Data | |||
Logs | System Log (events) | Sort Order
Date/Time Line/Page |
2*** | ||
WDS System Log (events) | 2*** |
(1) | Contact your Cat dealer for PIN code support. |
(2) | Must be enabled in setup function |
A Water Delivery System warning will appear in red text on the display screen. If a WDS warning appears, take appropriate action as directed by the message. If the appropriate action is not known, contact your Cat dealer or refer to Specifications / System Operation / Testing and Adjusting / Disassembly and Assembly / Troubleshooting, UENR2065, UENR3561, and UENR3533, "Water Delivery System". Some of the WDS warnings include, but are not limited to the following:
- Tank lift mode on (keypad disabled)
- Tank water level low (flashing "low" at bottom of water level gauge)
- Dirty filter (hydraulic)
- High oil temp
- Low hydraulic oil (WDS system disabled)
- High oil temp shutdown (audible alarm, WDS system disabled at 100 degrees)
- Hydraulic system press Hi (WDS system disabled
- Sensor Failure (Press F2)
A (diagnostic) error will appear on the display screen as a popup window. If an error appears, perform the appropriate maintenance to resolve the error. If the appropriate maintenance is not known, contact your Cat dealer or refer to Specifications / System Operation / Testing and Adjusting / Disassembly and Assembly / Troubleshooting, UENR2065, "Water Delivery System". Some of the WDS errors include, but are not limited to the following:
- No contact (this error can occur on any of the electrical components)
- Low error (this error can occur on any of the sensors)
- High error (this error can occur on any of the sensors)
- Startup error (this error can be temporarily cleared, but will reappear when the power is cycled)
Press "F2" in order to clear an error appearing on the display screen. If there are multiple errors, press "F3" to scroll to the next error