312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Caterpillar


Air Conditioning E14 - Ambient Air Temperature Sensor (Short Circuit)

Usage:

352F-VG A9J


Illustration 1g02393477
(1) Ambient air temperature sensor

Diagnostics



Illustration 2g02517078
Partial Electrical Schematic
(A) Connector
(C) Connector
(CC) Connector
(L) Connector
(1) Ambient air temperature sensor
(2) Control panel

  1. Disconnect ambient air temperature sensor (1) connector from connector (L). Measure the value of the resistance in the ambient air temperature sensor. See "Specifications" below for the correct resistance value. Proceed to Step 2.

  2. If the resistance value is incorrect, see Step 3. If the resistance value is correct, see Step 4.

  3. Replace the ambient air temperature sensor.

  4. Measure the voltage between the "RD/WH" wire and the "BR/WH" wire at connector (L). See "Specifications" below for the correct voltage. Proceed to Step 5.

  5. If the voltage value is incorrect, see Step 6. If the voltage value is correct, see Step 7.

  6. Disconnect connector (C) from connector (CC). Check the wiring harness between connector (L) and connector (C). Repair the wiring harness if faulty. Also, check the system power source. Refer to Systems Operation, "Air Conditioning System Electrical Schematic".

  7. Reconnect the ambient air temperature sensor connector to connector (L). Measure the voltage between "RD/WH" wire and the "BR/WH" wire at connector (CC). See "Specifications" below for the correct voltage. Proceed to Step 8.

  8. If the voltage values are incorrect, see Step 9. If the voltage values are correct, see Step 10.

  9. Disconnect connector (A) from control panel (2). Check the wiring harness between connector (CC) and connector (A). Repair the wiring harness if faulty.

  10. Reconnect connector (C) to connector (CC). Measure the voltage between the "RD/WH" wire and the "BR/WH" wire at control panel (2). If the voltage value is incorrect, replace the control panel.

Specifications



Illustration 3g02318095
Ambient Air Temperature Sensor Characteristics
(R) Resistance (k Ohms)
(T) Temperature (Ambient air)

Resistance in the ambient air temperature sensor

25° C (77° F) ... 1.7k Ohms

Voltage between connectors ... 5 VDC

Caterpillar Information System:

312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E13 - Ambient Air Temperature Sensor (Open Circuit)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E12 - Intake Air Temperature Sensor (Short Circuit)
797F Off-Highway Truck Power Train Differential and Bevel Gear - Disassemble
3516B Marine Auxiliary Engine Exhaust Shield
C13 Engines for Caterpillar Built Machines Nozzle Heater Harness - Remove and Install
3500B Engines for Caterpillar Built Power Modules Turbocharger Oil Lines
3516B Marine Auxiliary Engine Coolant Level Sensor
C13 Engine for Caterpillar Built Machines Solenoid Valve (Exhaust Balance) - Remove and Install
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E11 - Intake Air Temperature Sensor (Open Circuit)
C13 Engines for Caterpillar Built Machines Air Control Valve - Remove and Install - Control Module, Clean Emissions Module
C15 and C18 Petroleum Generator Sets Varistor - Inspect
C15 and C18 Petroleum Generator Sets Stator Winding Temperature - Test
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E15 - Water Temperature Sensor (Short Circuit)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E16 - Water Temperature Sensor (Short Circuit)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E21 - Evaporator Sensor (Open Circuit)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E22 - Evaporator Sensor (Short Circuit)
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E43 - Air Outlet Damper Error
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning E44 - Air Blend Damper Error
CX31 On-Highway Transmission Relief Valve (Transmission Hydraulic Control) - Test and Adjust
312E, 312F, 313F, 316E, 316F, 318E, 318F, 320E, 320F, 323E, 323F, 324E, 325F, 326F, 329E, 329F, 330F, 335F, 336E, 336F, 340F, 349E, 349F, 352F, 374F and 390F Excavators and 336E MHPU and 349E MHPU Mobile Hydraulic Power Units Air Conditioning and Hea Air Conditioning and Heating System Troubleshooting
C27 and C32 Industrial Engines Exhaust Elbow - Remove and Install - Clean Emissions Module Inlet
C27 and C32 Industrial Engines Catalyst - Remove and Install
2010/12/06 A Protective Boot Is Recommended for The Pressure Washing of certain C9 through C32 Marine Engines {1000, 1261, 7500, 795C}
Using the Communications Adapter 3{1900} Using the Communications Adapter 3{1900}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.