UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Caterpillar


Specifications

Usage:

UPS 750 CPM

Table 1
    50 Hz Units     60 Hz Units    
    UPS 250iE     UPS 500i     UPS 750i     UPS 300E     UPS 600     UPS 900    
Rating     250 kVA
2225 kW    
500 kVA
450 kW    
750 kVA
675 kW    
300 kVA
240 kW    
600 kVA
480 kW    
900 kVA
720 kW    
Input Voltage     380 VAC
400 VAC
415 VAC    
480 VAC    
Output Voltage     380 VAC
400 VAC
415 VAC    
480 VAC    
AC Input    
Nominal Amperage     358 A
340 A
328 A    
709 A
674 A
650 A    
1064 A
1011 A
974 A    
302 A     599 A     898 A    
Maximum Continuous Amperage     400 A     800 A     1200 A     400 A     800 A     1200 A    
Maximum Noncontinuous Amperage     420 A     840 A     1260 A     420 A     840 A     1260 A    
AC Output    
Nominal Amperage     380 A
361 A
348 A    
761 A
723 A
696 A    
1141 A
1084 A
1045 A    
361 A     723 A     1084 A    
Typical System Efficiency    
100 Percent load     97 Percent     98 Percent     98 Percent     97 Percent     98 Percent     98 Percent    
Physical Dimensions and Weight    
Height     1981 mm (1)
(78 in) (1)    
2438 mm (1)
(96 in) (1)    
Wireway Height     452 mm
(17.8 in)    
Depth     865 mm
(34 in)    
Width     3226 mm (2)
(127 in) (2)    
4318 mm (2)
(170 in) (2)    
5410 mm (2)
(213 in ) (2)    
3226 mm (2)
(127 in) (2)    
4318 mm (2)
(170 in) (2)    
5410 mm (2)
(213 in) (2)    
Weight     3500 kg
(7716 lb)    
5570 kg
(12280 lb)    
7610 kg
(16777 lb)    
3199 kg
(7050 lb)    
5241 kg
(11550 lb)    
7282 kg
(16050 lb)    
Cable Access     Top or Bottom    
Heat Rejection Nominal/Maximum    
kW     8.21     11.68     17.53     8.67     12.30     18.44    
BTU/Hr     28028     39839     59839     29612     41983     62975    
Specifications for Input    
Voltage     380 VAC/400 VAC/415 VAC, 3 phase, plus neutral and ground (3)     480 VAC, 3 phase plus ground(from grounded wye source) (4-wire optional)    
Voltage Range     480 VAC +10 Percent / −15 Percent (programmable) ± 10 Percent at 380 VAC    
Power Factor     0.99 at rated load and nominal voltage    
Harmonic Current Distortion    
Linear Load     less than 3 Percent max at 100 Percent linear load    
Nonlinear Load     less than 8 Percent with a 100 Percent nonlinear load    
Input Frequency     50 Hz ± 10 Percent max (programmable) ± 3 Percent (default) (4)     60 Hz ± 10 Percent max (programmable) ± 3 Percent (default    
Specifications for Withstanding Surge     Meets IEEE 587/ANSI C62.41    
Walk-In Time     Programmable from 1 second to 15 seconds    
Specifications for Output    
Voltage     380/400/415 VAC, 3 phase, plus neutral and ground (from grounded wye source)     480 VAC, 3 phase, plus ground (4-wire with optional 4-wire input)    
Overload Capability (Normal Operation without bypass)     1000 Percent for 10 milliseconds    
500 Percent for 1 second
up to 200 Percent for 30 seconds
up to 125 Percent for 10 minutes
Voltage Regulation    
Steady state     ± 1 Percent of nominal for ± 10 Percent input and balanced or unbalanced load    
Flywheel Mode     ± 1 Percent of nominal for steady-state balanced or unbalanced load    
Transient     ± 1 Percent within 50 milliseconds for 100 Percent load step    
Voltage Distortion     3 Percent of linear loads
5 Percent of non-linear loads    
Output Frequency     50 Hz ± 3 Percent (utility synchronized-normal operation) nominal ± 0.2 Percent free running     60 Hz ± 10 Percent (utility synchronized-nominal operation) nominal ± 0.2 Percent free running    
Slew Rate     Maximum of 1 Hz per second    
Environmental Specifications    
Audible Noise     less than 72 dBA at
1 m (3.28 ft)    
less than 75 dBA at
1 m (3.28 ft)    
less than 72 dBA at
1 m (3.28 ft)    
less than 75 dBA at
1 m (3.28 ft)    
Operating Temperature    
0 °C (32 °F) to
40 °C (104 °F)    
Storage Temperature    
−25 °C (−13 °F) to
70 °C (158 °F)    
Humidity     5 Percent to 95 Percent (non-condensing)    
Altitude     Up to
914 m (3000 ft) (derate operating temperature by
1.2° C (34.2° F) for every
305 m (1000 ft) above this limit)    
Emissions and Immunity     FCC Class A, Subpart J of Part 15 and EN 50091-2    
Minimum Floor Load Capacity    
147.4 kg (325 lb)per square foot    
( 1 ) This dimension excludes the wireway.
( 2 ) The N+1 option adds an additional 1092 mm (42.99 inch).
( 2 )
( 3 ) Except at 10 percent of maximum at 380 VAC.
( 4 ) Also available with 60 Hz nominal voltage.

Table 2
480 V Systems    
Percent of Load     Ride-Through Time    
100 Percent     14.3 seconds    
75 Percent     18.8 seconds    
50 Percent     27.8 seconds    
25 Percent     52 seconds    
380/400/415 V Systems    
Percent of Load     Ride-Through Time    
100 Percent     15 seconds    
75 Percent     20 seconds    
50 Percent     30 seconds    
25 Percent     56 seconds    

Caterpillar Information System:

UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Electrical System
UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Fire Prevention and Explosion Prevention
C6.6 Marine Generator Set Engine Oil and Filter - Change - Duplex Oil filters
3412, 3412C, and 3412E Generator Set Engines Indicator Lamp - Test
C6.6 Marine Generator Set Engine and Generator Mounting Group
2015/07/17 A New Cylinder Pack Is Now Used {1225, 1239}
UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Safety Signs and Labels
Reuse and Salvage for 3500 Engine Cylinder Blocks {0672, 0705, 0762, 1201, 1217} Reuse and Salvage for 3500 Engine Cylinder Blocks {0672, 0705, 0762, 1201, 1217}
CX28 On-Highway Transmission General Information
C6.6 Marine Generator Set Alternator
C6.6 Marine Generator Set Air Starting Motor
325 VARIABLE UNDERCARRIAGE VH Undercarriage/VM Undercarriage Hydraulic System Pressure Reducing Valve (Travel Parking Brake) - Test and Adjust - VM Undercarriage
2008/09/01 The Torque Specification on the Rocker Arm Bolts has Changed {1102, 1123}
3512B Generator Set Engine Speed Control (Switch) - Test
2008/09/01 New AccuGrade® 900 MHz and 2400 MHz Radios are Now Available {733T}
UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Information Plate
C6.6 Marine Generator Set Fuel Priming Pump - Remove and Install - MCS Fuel Priming Pump
3512B Generator Set Engine Speed/Timing - Test
3412, 3412C, and 3412E Generator Set Engines ECM/Personality Module - Test
3512B Generator Set Engine Starting - Test
UPS 300, UPS 301, UPS 500, UPS 600, UPS 750 and UPS 900 Uninterruptible Power Supplies Site Preparation
3508B, 3512B, 3516B, 3512C and and 3516C Auxiliary Engines, Generator Set Engines, and Generator Sets Generator Lead Connections
3412, 3412C, and 3412E Generator Set Engines Shutdown - Test
The Use of Unsupported Software Could Cause Unexpected Shifting on Certain TH48-E80 Oil/Gas Transmissions{3168, 7620} The Use of Unsupported Software Could Cause Unexpected Shifting on Certain TH48-E80 Oil/Gas Transmissions{3168, 7620}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.