Illustration 1 | g01340321 |
Illustration 2 | g01340326 |
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at
- Speed ... 6900 ± 1800 rpm
- Current draw ... 127.5 ± 27.5 amp
- Voltage ... 11 V
- Current draw ... 127.5 ± 27.5 amp
(1) Tighten the nut on the battery terminal to the following torque. ...
(2) Tighten the nut on the ground terminal to the following torque. ...
(3) Tighten the nut on the ground terminal to the following torque. ...
(4) Tighten the nut on the switch terminal to the following torque. ...
(5) Tighten the nut on the motor terminal to the following torque. ...
(6) Tighten the nut on the motor frame terminal to the following torque. ...
206-8789 Solenoid Kit
Current consumption at
- Pull-in windings at 10V ... 92.5 ± 7.5 Amp
- Hold-in windings at 10V ... 23 Amp